Permit Information
Permit NumberBLD19-04369
StatusIssued
Name CMC CONSTRUCTION
Site Address 10222 W USTICK RD
Project NameUstick 12-Plex
Customer Number 
ePlanReviewYes
Description
(USTICK 12-PLEX) //7-23-2020 PLAN MODIFICATION TO REVISE STRUTURAL FOOTING TO REFLECT WIDTH AND DEPTH REQUIREMENTS FOR HOLD DOWNS, INTERIOR PARTITION WALL FOOTINGS WIDENED, REVISED HOLD DOWN SCHEDULE, REVISION ADDED NOTE TO SHEET S6.0 TO MAKE GIRDER TRUSS DESIGN REQUIREMENTS CLEAR FOR TRUSS MFG. jg// Permit for the construction of a 15,151 sq. ft., 3-story, 12-unit apartment building. Work to include general site work and the construction of the new building per the approved plans, attached engineering and plan review report. Note: Special Inspections required see form 310. This building is to be fully fire sprinklered with a NFPA 13-R system as required for residential occupancy and story increase. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Foundation7/27/20207/27/20207/27/2020PPEND
DetailsTell Riley
Sergio - Foundation walls are outside of the modified footing area. */Screened*/ Phone #: ###-####//special inspection report, for post installed anchors, verified by pull test, was in compliance with design engineer--also engineer called me and verified//
//plans show hair pins at corners with hold down anchor bolts--engineer called and wants detail deleted from plans--advised to submit with current plan mod under review for footings//
//let GC know about my concerns with elevations, we discussed elevtations, wall height seems extremely high, wall currently 2' 8" above footing, plans show a 2' wall on structurals, will need to meet accessiblity requirements at finals//
//if walls are poured prior to acceptance of plan modification for footing changes and wall details, cantractor is pouring at own risk//
rebar appears to be installed per the current plans, less the hair pins on corners//
BLD-Footing7/15/20207/15/20207/15/2020PPART
DetailsTell Riley
Serigo *screened* Phone #: ###-####//SOUTH WALL FOOTINGS CLOUDED ON PLANS DATED 6/22/2020 THAT ARE NOT APPROVED PLANS, CONTRACTOR POURING AT OWN RISK UNTIL PLAN MODIFICATION IS SUBMITTED AND APPROVED//REBAR IN THIS LOCATION APPEARS TO BE INSTALLED PER THESE PLANS//areas outside modified footings are ok per the APPROVED plans//advised contractor PLAN MODIFICATION MUST BE APPROVED PRIOR TO GOING VERTICAL WITH FRAMING//maintain all clearances on rebar//
BLD-Footing7/13/20207/13/20207/13/2020PNR
DetailsTell Riley
Call ahead Sergio - Phone #: ###-####//need to submit to plan review for modifications to structural plans for footing sizes, depths and rebar//also appears to be changes with the roof trusses per the new structural drawings onsite//rebar clearances need to be adjusted/cut away from forms and elevated 3" above grade//
BLD-Footing7/6/20207/7/20207/7/2020AFAIL
DetailsTell Riley
Sergio Phone #: ###-####//CN posted//need small documents//special inspections reqiured//rebar does not meet installation requirements on plans//site does not meet minimum ESC requirements//need all property lines identified and/or marked//