Permit Information
Permit NumberBLD19-04769
StatusFinaled
Name DAVE EVANS CONSTRUCTION
Site Address 6305 W OVERLAND RD Unit: 110
Project NameICOA - Suite #110
Customer NumberBLD19-04869
ePlanReviewYes
Description
**(IDAHO COMMISSION ON AGING – SUITE #110)** (2 BUILDING PERMITS UNDER BLD19-04769 in EPLAN) //Note: a plan modification was done under BLD19-04869, see scope of work in that permit. JG) Permit is to remodel an existing 7,072 sq. ft. tenant space by dividing it into two separate tenant spaces, this tenant space is to be 3,761 sq. ft. and the remaining 3,311 sq. ft. is to be an unoccupied tenant space created under BLD19-04869. Approval is contingent upon adhering to the approved plans on file and attached engineering. Work to include: removal of select interior bearing and nonbearing walls, removal of select door/door frame, select new exterior stucco finish, select new exterior storefront doors, select new exterior site concrete work, construction of select interior nonbearing wall to demise tenant spaces, select interior wall infill, select new interior bearing opening design per engineering, electrical work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/29/20201/29/20201/29/2020PPASS
DetailsTell Riley
Ben Covert Phone #: ###-####//trades ok//final complete per plans//
FIRE-Final Inspection1/29/20201/29/20201/29/2020PPASS
DetailsTroy Cobbley
Life safety passed.

Ben Covert Phone #: ###-####
BLD-Conference1/24/20201/27/20201/27/2020ADONE
DetailsMike Jordan
ben Phone #: ###-####. Will be ok for final once fire/life/safety finals.
FIRE-Final Inspection1/23/20201/24/20201/24/2020AFAIL
DetailsTroy Cobbley
Life safety will be ok to final when the fire sprinkler permit has been inspected/finaled.

Ben Phone #: ###-####
BLD-Final1/23/20201/24/20201/24/2020ANR
DetailsMike Jordan
Ben Phone #: ###-####
FIRE-Final Inspection1/22/20201/23/20201/23/2020AFAIL
DetailsTroy Cobbley
Fire alarm panel needs to be cleaned up, fire sprinkler permit needed for modifications, new door hardware to be single action type, repair exit signs and emergency lights.


Ben Phone #: ###-####
BLD-Final1/22/20201/22/20201/22/2020PNR
DetailsJim Storey
Ben Phone #: ###-#### need sign offs
BLD-Framing/Rough-in1/8/20201/8/20201/8/2020PPART
DetailsMike Jordan
call for access - ben Phone #: ###-####. Interior wood framed walls ok. Contractor to get RFI from engineer of record to approve the use of 2x4 in leiu of 2x6 wood studs for neww beam support.