Permit Information
Permit NumberBLD19-04916
StatusFinaled
Name STRAIGHT LINE BUILDING SOLUTIONS LL
Site Address 2592 E BEVERLY ST Unit: 128
Project NameTurf Equipment & Agronomics
Customer Number 
ePlanReviewYes
Description
(TURF EQUIPMENT & AGRONOMICS LLC - BUILDING B - SUITE #128) This building is fire sprinkled for area increase and fire area. Permit is to construct tenant improvements within a new 37,200 sq. ft. building (Shell under BLD18-02802) to make a 4,592 sq. ft. tenant space for office and warehouse use (435 sq. ft. office area + 4,020 sq. ft. warehouse area). Approval is contingent upon adhering to the approved plans on file and plan review report. Work to include: construction of interior non-bearing walls to create demising wall, an office, an open front office area and an accessible bathroom, door/door frames, suspended acoustic and gypsum ceiling, (1) new RTU’s to be installed with associated ductwork, electrical work, plumbing work, mechanical work and Interior finishes shall be in compliance with chapter 8 of the 2015 IBC. This building is fully fire sprinkled with an approved fire alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/27/20203/30/20203/30/2020APASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Todd Landvatter
FIRE-Final Inspection3/27/20203/30/20203/30/2020APASS
DetailsTroy Cobbley
Life safety passed. No fire alarm. Card signed.

Phone #: ###-#### Inspection requested via web by Todd Landvatter
BLD-Ceiling Grid Inspection3/20/20203/23/20203/23/2020APART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Todd Landvatter. Ceiling grid ok pending mech. rough in inspection.
BLD-Ceiling Grid Inspection3/20/20203/20/20203/20/2020PCANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Todd Landvatter Inspection cancelled from web by: Todd Landvatter
BLD-Framing/Rough-in2/18/20202/19/20202/19/2020APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Todd Landvatter. Interior steel stud framed walls ok for cover. Hardlids will be ok for cover pending fire sprinkler and mech. rough in inspections.
BLD-Conference2/13/20202/13/20202/13/2020ADONE
DetailsMike Jordan
please call first Phone #: ###-#### Inspection requested via web by Todd Landvatter