Permit Information
Permit NumberBLD20-00141
StatusFinaled
Name IDACS LLC
Site Address 1290 W MYRTLE ST Unit: 460
Project NameNew York Life - 4th Story
Customer Number 
ePlanReviewYes
Description
(NEW YORK LIFE – PIONEER CROSSING OFFICE BUILDING – 4TH STORY – WEST END) The fire sprinkler system is used for building area increase, for height increase, and for story increase. To construct a 6,879 square foot office tenant space on the 4th story of an existing 5 story building. The common core will be expanded by constructing a 473 square foot extension to the existing common corridor so that it wraps entirely around the core restrooms. Work is to include interior nonbearing walls, interior doors, interior windows/glass walls, two sinks accessible to the disabled with knee and toe clearance for a front approach, suspended acoustical ceilings, gypsum board soffits and bulkheads, millwork, and finishes. Perhaps a horizontal sliding folding partition will be installed. If so, additional beams will be installed to support the partition. Special Inspection is required for welding and for bolting. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/20/20205/21/20205/21/2020PPEND
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Korey Hall ok for tco
FIRE-Final Inspection5/19/20205/20/20205/20/2020PPASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, mag locks release on general fire alarm, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work is complete, signatures provided on permit sign off card.

Phone #: ###-#### Inspection requested via web by Korey Hall
BLD-Ceiling Grid Inspection5/4/20205/5/20205/6/2020PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Korey Hall
BLD-Framing/Rough-in3/26/20203/26/20203/26/2020PPASS
DetailsDave Hannah
Re-Inspection of in wall floor penetration fire caulking Phone #: ###-#### Inspection requested via web by Korey Hall
BLD-Framing/Rough-in3/25/20203/25/20203/25/2020PNR
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Korey Hall needs to fire stop holes in floor