Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD20-00295
StatusIssued
Name RADIX CONSTRUCTION INC
Site Address 11211 W FAIRVIEW AVE
Project NameStarbucks Building Shell
Customer Number 
ePlanReviewYes
Description
(STARBUCKS - BUILDING SHELL) (CUP19-00075) (DRH19-00501) This building does not have a fire sprinkler system. Permit to construct new 2,200 sq ft restaurant shell building with drive through. This shell permit is not intended to establish a Certificate of Occupancy for any portion of the building. Approval is contingent upon adhering to the approved plans on file. Work is to include: concrete footings and stem wall, wood stud walls, wood shear walls with hold downs, steel columns, wood headers, engineered wood roof trusses, wood roof sheathing, exterior windows, exterior doors, exterior wall finishes, roof insulation installed on top of the roof deck, and a roof covering. Masonry trash enclosure with steel gates and drive through cover will also be constructed. Special inspections required for soils, concrete, masonry and steel welding. **JJN**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Wall Bracing6/30/20207/1/20207/1/2020APASS
DetailsMike Jordan
Could not answer questions......shear // rod Phone #: ###-####. Interior shear wall ok.
BLD-Wall Bracing6/30/20206/30/20206/30/2020PNR
DetailsMike Jordan
Rod *screened* Phone #: ###-####
BLD-Energy code compliance6/23/20206/23/20206/23/2020PPASS
DetailsMike Jordan
Screened- Rod Phone #: ###-####
BLD-Framing/Rough-in6/18/20206/18/20206/18/2020PPASS
DetailsMike Jordan
screened // rod Phone #: ###-####
BLD-Framing/Rough-in6/8/20206/9/20206/9/2020PCANC
DetailsMike Jordan
screen walls on roof for mechanical - Rod Phone #: ###-####
BLD-Wall Bracing6/5/20206/5/20206/5/2020PPASS
DetailsMike Jordan
Rod *screened* Phone #: ###-####. Exterior walls and roof ok.
BLD-Framing/Rough-in6/1/20206/2/20206/2/2020ACANC
DetailsMike Jordan
roof nailing - Rod *screened* Phone #: ###-####. Will reschedule.
BLD-Concrete5/15/20205/18/20205/18/2020APASS
DetailsMike Jordan
slab and vabor Rob Phone #: ###-####
BLD-Foundation5/12/20205/13/20205/13/2020PPASS
DetailsMike Jordan
Screened-foundation insulation inspection- Rod Phone #: ###-####
BLD-Foundation5/5/20205/7/20205/7/2020PPASS
DetailsMike Jordan
Rod Phone #: ###-####. column pedestals for drive thru.
BLD-Footing4/30/20205/1/20205/1/2020PPART
DetailsMike Jordan
screened // Rod Phone #: ###-####. Column pad footings for trellis . Ok to place concrete pending special inspection.
BLD-Energy code compliance4/20/20204/21/20204/21/2020APASS
DetailsMike Jordan
screened // rod Phone #: ###-####. rigid insulation on stemwall.
BLD-Foundation4/15/20204/17/20204/17/2020APART
DetailsMike Jordan
Rod Phone #: ###-####. Perimeter stemwall. Noted column ties at brace frame not per plan. Special inspector to make note of repair prior to concrete placement.
BLD-Footing4/10/20204/13/20204/13/2020PPASS
DetailsMike Jordan
Rod Phone #: ###-####. Perimeter footings ok.