Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberBLD20-00330
StatusFinaled
Name SEAN CAFFERTY ENTERPRISES
Site Address 3939 S TRANSPORT ST
Project NameTreabar Financial
Customer NumberCZC20-00030
ePlanReviewYes
Description
(TREBAR) Permit is to remodel an existing 6,536 sq. ft. tenant space. **NOTE: ANY FUTURE SUBSTANTIAL TENANT IMPROVEMNTS SHALL REQUIRE THE BUIDING TO BE SEPERATED INTO TWO SEPARATE BUILDINGS AND OR FIRE SPRINKLERED TO BECOME IN COMPLIANCE WITH BUILDING AREA, CURRENTLY BUILDING IS IN NONCOMPLIANCE WITH THE CODE IN EFFECT WHEN THE ADDITIONS WERE BUILT (UNDER THE 1976 UBC AND WITH THE CURRENTS CODES 2015 IBC). SINCE THERE WAS NO CHANGE IN USE OR OCCUPANCY UNDER THIS PERMIT THERE WAS NO TRIGGER TO MAKE BUILDING COMPLY.** Approval is contingent upon adhering to the approved plans on file, attached engineering and plan review report. Work to include: removal of select exterior windows, removal of select exterior wall, removal of select exterior and interior door/door frames, removal of select interior nonbearing walls, removal of select interior stairs and frame infill floor, removal of select plumbing fixtures, removal of Rail-Lift system beam and column, construction of select exterior wall per design, construction of interior non-bearing walls, select exterior and interior wall infill, new door/door frames, new exterior overhead door, new exterior windows, new 1-hour rated exit stairway, new Hi/Lo drinking fountain, new acoustic suspended and gypsum ceiling, three new accessible restrooms, new accessible shower, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the 2015 IBC. This building is not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/4/20208/4/20208/4/2020PDONE
DetailsJim Storey
*Screened* Bob Phone #: ###-####
BLD-Final8/4/20208/4/20208/4/2020APASS
DetailsJim Storey
final ok
FIRE-Final Inspection8/3/20208/4/20208/4/2020APASS
DetailsJim Page
Previously noted items have been corrected, no fire sprinklers, no fire alarms, duct detectors are stand-alone and functional with annuciators, fire extingiushers are placed with current inspection tags. Final life fire safety inspection complete, signature card not available at time of inspection.

Sean *screened* Phone #: ###-####
FIRE-Final Inspection7/31/20207/31/20207/31/2020PFAIL
DetailsTroy Cobbley
Remove deadbolt at the west door, provide exit discharge light at the south facing door per approved plans, install duct smoke detector per installation guide (narrow side) and provide testing, provide tagged and mounted fire extinguisher up stairs.


SCREENED // Bob Phone #: ###-####
BLD-Energy code compliance5/19/20205/21/20205/21/2020APASS
DetailsJim Storey
screeened / Bob Phone #: ###-####
BLD-Framing/Rough-in5/19/20205/21/20205/21/2020APASS
DetailsJim Storey
screeened / Bob Phone #: ###-####
BLD-Conference5/19/20205/20/20205/20/2020APASS
DetailsJim Storey
screeened / Bob Phone #: ###-####