Permit Information
Permit NumberBLD20-01078
StatusIssued
Name ALTECCA LLC
Site Address 350 N MITCHELL ST Unit: 370
Project NameAccess 2 care T.I.
Customer Number 
ePlanReviewYes
Description
(ACCESS 2 CARE T.I. AND EXPANSION) //7-13-2020 PLAN MODIFICATION TO CREATE OFFICE IN A DIFFERENT LOCATION WITHIN THE TENANT SPACE. // This building is fire sprinkled for area increase. Permit to remodel an existing 9,800 sqft. office tenant space and to expand into adjacent 7,715 sqft. space for a total of 17,515 sqft. tenant area. Work to include: demo non-bearing interior partitions, handrail and guard, portion of storefront glazing, ramp and raised platform, new construction of non-bearing interior partitions, doors, ramp and handrails, relocate lighting fixtures and lay-in ceilings, mechanical work, electrical work, and new finishes. Interior finishes shall be in compliance with 2015 IBC Ch. 8. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise fire department. **MDH**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/28/20207/28/20207/28/2020PPASS
DetailsMike Jordan
screened // Duane Phone #: ###-####
FIRE-Final Inspection7/28/20207/28/20207/28/2020PPASS
DetailsTroy Cobbley
Life safety passed.

Call for access lockbox on door. Dwayne- */Screened*/ *jobsite is vacant Phone #: ###-####
BLD-Final6/25/20206/25/20206/25/2020PNR
DetailsMike Jordan
Duane - Altecca Construction
Door code 1940 if not there Phone #: ###-#### Inspection requested via web by Duane Seid. Fire/life/afety has failed.
FIRE-Final Inspection6/25/20206/25/20206/25/2020PFAIL
DetailsTroy Cobbley
Provide plan mods for wall changes and provide the exit signs and emergency lightng as shown.

Duane - Altecca Construction
Door code 1940 if not there Phone #: ###-#### Inspection requested via web by Duane Seid
BLD-Framing/Rough-in5/7/20205/8/20205/8/2020APASS
DetailsMike Jordan
Duane Phone #: ###-####. Interior steel stud framed walls ok.