Permit Information
Permit NumberBLD96-02023
StatusFinaled
Name THRIFTY NICKEL
Site Address 6604 W OVERLAND RD
Project Name 
Customer Number 
ePlanReviewNo
Description
To convert a 2,010 sq.ft. one story dwelling with 1,312 sq.ft. basement to an office building. Work to include installing 2nd exit from basement by way of stairs up to grade on exterior of north side of building. Installation of 5/8 sheetrock on ceiling of basement. Construction of 1-hr rated enclosure with a 20 min rated door assembly in basement at bottom of existing stairs. Construction of accessible handicap ramp to south entrance. Upgrading exsiting restroom to be accessible. And miscelaneous remodeling to the interior of building. All work to be done per approved plans on file. This building originally was granted Planning Department approval under CU-5-82 and DR-14-82 but never completed the building conversion to receive a certificate of occupancy. This permit and completed plans reflects work to be done to complete the conversion. (Temporary occupancy to be allowed under MIS96-1083 for 1st floor only.) (P.C.#413-96)RMH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP - Final3/16/19993/17/19993/17/1999ACANC
DetailsCarl Dependahl
03/17/99 340 - RON ###-#### done 3-15-99
Permanent Occupancy 3/16/19993/16/1999 DONE
Details
INSP - Final3/12/19993/15/19993/15/1999APART
DetailsTom Arcoraci
03/15/99 408 - OK FOR PERM OCC AFTER CODE INFORCEMENT OK
INSP - Final3/11/19993/12/19993/12/1999AFAIL
DetailsCarl Dependahl
03/12/99 340 - ron ###-#### call first called, went by, no one at site
INSP-Final Inspection3/10/19993/11/19993/11/1999APASS
DetailsJoe Tawney
03/11/99 406 - REINSP OK FOR CERT OF COMPLETION NO TENANT
INSP-Final Inspection3/9/19993/10/19993/10/1999AFAIL
DetailsJoe Tawney
03/10/99 406 - REINSP FAIL DOOR HDWRE, EXIT SIGNS
INSP - Final2/11/19993/8/19993/8/1999PFAIL
DetailsCarl Dependahl
03/08/99 340 - need 4" spacing at guardrail, other sig's, keep cn
INSP-Final Inspection2/11/19992/12/19992/12/1999AFAIL
DetailsRick Jackson
02/12/99 406 - ron finner ###-#### fn fire call 1st before insp repair 1 hr lid in basement; rear exit hardware
INSP - Final2/10/19992/11/19992/11/1999AFAIL
DetailsCarl Dependahl
02/11/99 340 - ron ###-#### c/n, need occ. card & all sigs. handrails, e
INSP - Footings12/1/199712/1/199712/1/1997PPASS
Details
12/01/97 338 - STAIRWELL IN BACK OF BLDG made ok
INSP - Framing/Rough-in11/12/199711/12/199711/12/1997PNH
Details
THRIFTY NICKEL--PLEASE CALL RON AT PAGER ###-#### TO MEET YOU. no access
INSP - Conference10/29/199710/30/199710/30/1997APART
Details
PHONE CONVERSATION WITH WORKER WILL MEET HIM ON SITE TOMORROW FIRST THING IN THE A.M.
INSP - Conference10/30/199710/30/199710/30/1997 FAIL
Details
/ / 333 - no one there