Permit Information
Permit NumberBLD99-02073
StatusFinaled
Name RONALD HENRY
Site Address 2233 E ROANOKE DR
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 2462 sq. ft. two story single family dwelling with a 492 sq. ft. covered front porch area and a 704 sq. ft. detached three car garage per approved plans, all engineering/red-lining and attached requirement lists. (1st floor 1334 sq. ft.)(2nd floor 1128 sq. ft.) This lot is located within a hillside area and is subject to the hillside ordinances. Class "A" roof system to be installed. PC #600 CFH99-0020 DJO
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/28/20001/31/20001/31/2000APASS
DetailsRuss Owen
Ron ###-####. approved wall blocked of hallway 1/31/00 1:19:31 PM
BLD-Final1/27/20001/27/20001/27/2000PFAIL
DetailsRuss Owen
Ron Henry ###-#### head height at stairs \hallway safety fides at upper bath 1/28/00 1:40:06 PM
BLD-Final1/21/20001/21/20001/21/2000PFAIL
Details
Ron ###-####. Verify terry records has approved hillside requiremets ###-#### prior to final.. t. records still not signed off called and left message on contact answering machine. 1/24/00 8:06:48 AM
BLD-Framing/Rough-in12/1/199912/2/199912/2/1999APASS
DetailsWes Worcester
ron --###-#### fr insp
BLD-Foundation11/29/199911/30/199911/30/1999APART
DetailsRuss Owen
ron ###-#### Notified contractor at site to gain minimum 2" clearance at lower section of wall.
BLD-Framing/Rough-in11/24/199911/26/199911/26/1999PFAIL
DetailsRuss Owen
Scheduled by a contractor via Hello! on 11/24/1999 at 11:12:51. Contact: ###-####. (1) item left for engineering.
BLD-Footing11/22/199911/23/199911/23/1999APASS
DetailsRuss Owen
Jerry Nicalona ###-#### Footing at retaining wall.
BLD-Framing/Rough-in11/15/199911/16/199911/16/1999AFAIL
DetailsRuss Owen
RON ###-####
BLD-Framing/Rough-in11/12/199911/15/199911/15/1999AFAIL
DetailsRuss Owen
Scheduled by a contractor via Hello! on 11/12/1999 at 15:25:59. Contact: ###-####. Ext. shear required approval by engineer, no framing inspections will be done until resolved.
BLD-Framing/Rough-in11/12/199911/12/199911/12/1999PCANC
DetailsRuss Owen
ron ###-#### reinspect Called and told them to recall.
BLD-Framing/Rough-in11/9/199911/10/199911/10/1999PFAIL
DetailsWes Worcester
RON-- ###-#### FR INS Do not cover- no shear inspection, sided, BCEC incomplete & garage shear is wrong.
INSP - Foundation9/10/19999/13/19999/13/1999PPASS
DetailsRuss Owen
GARAGE FOUNDATION WALLS
INSP - Foundation9/7/19999/9/19999/10/1999ACANC
DetailsRuss Owen
Scheduled by a contractor via Hello! on 09/07/1999 at 16:55:16. Contact: ###-####. CANCELLED BY CONTRACTOR
INSP - Foundation9/9/19999/9/19999/9/1999PPASS
DetailsRuss Owen
all foundation complete now, except garage walls
INSP - Foundation9/9/19999/9/19999/9/1999 CANC
DetailsRuss Owen
9/9 Needs PM inspection. jrb
INSP - Foundation9/7/19999/8/19999/7/1999PCANC
DetailsRuss Owen
Scheduled by a contractor via Hello! on 09/07/1999 at 16:52:59. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on 09/07/1999 at 16:54:15.
INSP - Foundation9/1/19999/2/19999/2/1999APASS
DetailsRuss Owen
09/02/99 407 - steve- ###-#### ft insp
INSP - Foundation8/31/19999/1/19999/1/1999AFAIL
DetailsRuss Owen
09/01/99 407 - left corrections.
INSP - Foundation8/31/19999/1/19999/1/1999ACANC
DetailsRuss Owen
09/01/99 407 - called in 2 times.
BLD-Grading Inspection1/25/20001/25/20001/25/1999 BOND
DetailsRita DeYoung
Engineer has recommended $2800.00 bond for incomplete grading and drainage. Grading is conditionally approved upon receipt of $2800.00 surety. CALL CATHY @ ###-#### the bond has been submitted per Terry Records