Permit Information
Permit NumberBLD99-03134
StatusFinaled
Name BEAVER RIVER POWER CO. BLDG.
Site Address 621 S 17TH ST
Project NameBEAVER RIVER POWER CO
Customer Number 
ePlanReviewNo
Description
(BEAVER RIVER POWER COMPANY BUILDING) This building is being fire sprinklered to substitute for 1-hr fire-resistive construction. To upgrade an existing building shell and core. The mechanical mezzanine is being expanded by 225 square feet. Work is to include a fire sprinkler system throughout, 2 restrooms accessible to the disabled, 2 interior stairways, 1 exterior stairway, new openings in existing masonry walls, new interior doors/windows, new exterior doors, and mechanical/electrical infrastructure all per approved drawings and plan review conditions on file. Tenant improvement permits shall be applied for separately. This permit does not establish a Certificate of Occupancy for any tenant. The fire sprinkler system shall comply with NFPA 13-1996 as regulated by the Fire Department. DRH99-0199 CVA99-0022 PC-833-99 **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/26/200010/27/200010/27/2000APART
DetailsJim Storey
FN OCC-- MARK ###-#### need special insp. stamped letter/achd/all others perm sign off. 10/27/2000 5:24:55 PM
FIRE-Final Inspection10/26/200010/27/200010/27/2000APASS
DetailsRick Jackson
MARK ###-#### FIRE FN
FIRE-Final Inspection10/25/200010/26/200010/26/2000AFAIL
DetailsRick Jackson
Mark ###-#### need knox box 10/26/2000 12:02:15 PM
BLD-Framing/Rough-in10/19/200010/20/200010/20/2000PCANC
DetailsRick Jackson
###-####
FIRE-Final Inspection10/19/200010/20/200010/20/2000PCANC
DetailsRick Jackson
###-#### called by mark brown
FIRE-Final Inspection10/13/200010/19/200010/19/2000AFAIL
DetailsRick Jackson
MIKE-- ###-#### FIRE FN tested alarms - notification okay; need duct detectors for AHU shutdown installed; //need landings at exits; need sprinklers installed in room by restrooms; heads replaced that are painted 10/19/2000 3:18:22 PM
BLD-Concrete10/16/200010/16/200010/16/2000PPART
DetailsCarl Dependahl
Added by Inspector: 340 On 10/16/2000 w/ bldr...need eng's reports, etc
FIRE-Conference9/28/20009/29/20009/29/2000APART
DetailsRick Jackson
###-#### talked about requiremments for an upcoming event. told him all requirements for shell and any other approval per building official. tenent plans haven't been approved yet. 9/29/2000 10:28:58 AM
BLD-Framing/Rough-in9/26/20009/26/20009/26/2000PPART
DetailsJim Storey
r/i-- mark ###-#### framing on restarooms and fur out for kitchen ok unclear as to permit numbers and city has approved plan talked with dan s. for clearity in plan review. 9/26/2000 5:29:25 PM