Code Occupancy Approval | | | 7/29/2005 | | FAIL |
|
|
|
Failed. Issued a Correction Notice for:
Replace dead tree in front of building
Relocate dumpster to an enclosed area
Place curbing around landscaped areas by entrance/exit
Fill in deep spots/holes on the west and east side of the main entry.
|
BLD-Aging Inspection | 9/15/2004 | 9/15/2004 | 9/15/2004 | | CANC |
Tom Arcoraci
|
|
|
|
BLD-Aging Inspection | 7/15/2004 | 7/15/2004 | 7/15/2004 | | CANC |
Tom Arcoraci
|
|
|
|
BLD-Aging Inspection | 4/5/2004 | 4/5/2004 | 4/5/2004 | | NR |
Tom Arcoraci
|
|
|
|
BLD-Final | 2/2/2004 | 2/3/2004 | 2/3/2004 | A | NR |
Troy James
|
|
|
Dennis; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
FIRE-Final Inspection | 2/2/2004 | 2/2/2004 | 2/2/2004 | A | PASS |
Troy Cobbley
|
|
|
Fire life safety, fire alarm and fire sprinklers finaled
|
FIRE-Final Inspection | 1/21/2004 | 1/22/2004 | 1/22/2004 | A | FAIL |
Troy Cobbley
|
|
|
Need the security system/fire alarm drawings issued and inspected. All other life safety items are ok 1/22/2004 10:34:51 AM
|
BLD-Aging Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 | | PASS |
Tom Arcoraci
|
|
|
wip ok to continue 9/25/2003 8:32:05 AM
|
BLD-Framing/Rough-in | 3/5/2003 | 3/5/2003 | 3/5/2003 | P | PASS |
Tom Arcoraci
|
|
|
###-#### ken partial grid 3/5/2003 4:01:00 PM
|
BLD-Framing/Rough-in | 8/16/2002 | 8/19/2002 | 8/19/2002 | A | PART |
Tom Arcoraci
|
|
|
DENNIS ###-#### DRAFT STOP ON ROOF wip ok 8/19/2002 10:34:49 AM
|
BLD-Framing/Rough-in | 8/2/2002 | 8/5/2002 | 8/5/2002 | P | PART |
Tom Arcoraci
|
|
|
dennis ###-#### roof ok 8/5/2002 4:20:54 PM
|
BLD-Framing/Rough-in | 7/17/2002 | 7/18/2002 | 7/18/2002 | A | PART |
Tom Arcoraci
|
|
|
###-#### ok to cover ext dec colms 7/18/2002 10:56:39 AM
|
BLD-Framing/Rough-in | 7/3/2002 | 7/3/2002 | 7/3/2002 | P | PASS |
Tom Arcoraci
|
|
|
dennis- ###-#### fr
|
BLD-Framing/Rough-in | 7/1/2002 | 7/1/2002 | 7/1/2002 | P | FAIL |
Tom Arcoraci
|
|
|
###-#### 2 trimmers required at windows see plan 7/1/2002 2:15:15 PM
|
BLD-Foundation | 3/8/2002 | 3/11/2002 | 3/11/2002 | A | PART |
Tom Arcoraci
|
|
|
stem wall- ted-- ###-####-at front of bld
|
BLD-Footing | 3/4/2002 | 3/5/2002 | 3/5/2002 | A | PASS |
Tom Arcoraci
|
|
|
###-#### GEORGE pending spec insp 3/4/2002 5:19:44 PM
|
BLD-Framing/Rough-in | 2/28/2002 | 3/1/2002 | 3/1/2002 | A | PART |
Jim Sly
|
|
|
Scheduled by Inspector: 408 On 2/28/2002 4:48:30 PM C/N....Need letter stating change of Architect of record, Do not go beyond scope of "approved" work, Provide detail for headers Etc. 3/1/2002 9:48:32 AM
|
BLD-Framing/Rough-in | 2/28/2002 | 2/28/2002 | 2/28/2002 | P | CANC |
Tom Arcoraci
|
|
|
ted ###-####
|
BLD-Footing | 2/25/2002 | 2/25/2002 | 2/25/2002 | A | PART |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 02/25/2002 at 07:25:16. Contact: ###-####. pnding spec insp 2/25/2002 10:00:14 AM
|
BLD-Footing | 2/18/2002 | 2/20/2002 | 2/20/2002 | P | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 02/18/2002 at 15:05:13. Contact: . pending mti 2/20/2002 2:53:32 PM
|
BLD-Footing | 2/18/2002 | 2/19/2002 | 2/19/2002 | A | FAIL |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 02/18/2002 at 15:04:10. Contact: .Special inspection required by plans and footing for ramp shown to be 20 In wide has been constructed as 14 in , a c/n is posted owner and foundation contractor on site, Along with concrete truck, Note I received a call from foundation contractor this morning and he indicated to please make him my last stop as he would not be ready untill 12:00. Note Inspection done at this time also. 2/19/2002 1:00:48 PM
|
BLD-Footing | 2/8/2002 | 2/8/2002 | 2/8/2002 | P | PASS |
Tom Arcoraci
|
|
|
ted- ###-#### ft ok for footing under floor for col 2/8/2002 1:29:29 PM
|
BLD-Conference | 4/24/2001 | 4/24/2001 | 4/24/2001 | A | CANC |
Tom Arcoraci
|
|
|
Ted Sigmont ###-####
|
BLD-Conference | 4/24/2001 | 4/24/2001 | 4/24/2001 | P | PASS |
Tom Arcoraci
|
|
|
Scheduled by Inspector: 408 On 4/24/2001 11:07:53 AM conf on bath 4/24/2001 2:45:50 PM
|