Final | 10/16/2006 | 10/18/2006 | 10/18/2006 | P | PASS |
Bob Reichert
|
|
|
chuck ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corrections made, ok to final
|
Electrical Rough-In | 10/3/2006 | 10/4/2006 | 10/4/2006 | A | PASS |
Jim Schmer
|
|
|
Jim charles cell # is ###-#### see my notes to inspection request 10-03-06 ? call me remove outlet in 2 wire circuit, 2 gang bx next to door wires to short, remove baffles in wireway-chng to soffett with openings for lb and jbox, put grd wire in conduit jms
|
Electrical Rough-In | 10/2/2006 | 10/3/2006 | 10/3/2006 | P | FAIL |
Jack Frank
|
|
|
Charles no #, will call you to arrange time corr. posted 03-06-06, 314.16 box fill, remove all devices installed so I can inspect makeup room back of garage not done, 10-03-06, built his own jbox, wireway ? dose not meet NEC 314.40,41 has high and low voltage mixed in it, 300.14 needs 6" free length conductor all locations,250.130 (C) 1,2,3,4,5 nongrounding recept replacement or branch circuit extensions shall meet rquirements as code noted states, or see 406.3 (D) for gfci protection for ungrounded systems, 300.3(B) shall install equip grd wire in raceway not on the outside of it 1/2 EMT in homemade jbox
|
Electrical Rough-In | 3/6/2006 | 3/6/2006 | 3/6/2006 | P | FAIL |
Jack Frank
|
|
|
charles-- ###-####-- call 1st before insp cor. posted met owner210.70 needs fixture for outside exit entry 314,29 LB shall not be cover, 406.8(B) needs inuse cover, BCC no violation retained remove all cord used as fixed wiring,, remove all devices from boxes so I can inspect, update permit for 2 rooms COW
|
Conference | 2/5/2004 | 2/5/2004 | 2/5/2004 | P | PART |
Jack Frank
|
|
|
chuck please call for access; Phone #: ###-#### Internet Inspection Request from: Annette Moore 01 ok 2/5/2004 1:46:47 PM
|