Permit Information
Permit NumberELE05-00187
StatusFinaled
Name JENNIFER SHAW
Site Address 12239 W PALM CT
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/10/20053/10/20053/10/2005PPASS
DetailsBob Reichert
Jennifer; Phone #: ###-#### Internet Inspection Request from: Jan Rice gfci problem fixed. ok to final 3/10/2005 2:35:09 PM
Final3/9/20053/9/20053/9/2005PFAIL
DetailsMike Kinnear
jennifer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore gfci not working 3/9/2005 1:04:44 PM
Final3/8/20053/8/20053/8/2005PFAIL
DetailsBob Reichert
jennifer -; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie 2 bath gfci not working, 1 cfci wired backward. Need to call again 3/8/2005 2:55:48 PM
Final3/7/20053/7/20053/7/2005PFAIL
DetailsBob Reichert
jennifer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore met with owner, recpts had open grounds in 3 places, gfcis not wired correctly and in wrong place in ckt. Will call again. 3/7/2005 3:51:28 PM
Electrical Rough-In2/1/20052/2/20052/2/2005ACANC
DetailsBob Reichert
Jennifer; Phone #: ###-#### Internet Inspection Request from: Jan Rice
Electrical Rough-In2/2/20052/2/20052/2/2005PPASS
DetailsBob Reichert
Jennifer; Phone #: ###-#### Internet Inspection Request from: Jan Rice corrections made ric ok 2/2/2005 1:58:03 PM
Electrical Rough-In2/1/20052/1/20052/1/2005PNR
DetailsBob Reichert
late afternoon please///jennifer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Talked to framer, and owner had to leave, so he wasn't home. He had fixed a portion of the job, but appeared to have quite a bit of work to do before he was ready for an inspection. 2/1/2005 4:16:10 PM
Electrical Rough-In1/28/20051/31/20051/31/2005AFAIL
DetailsBob Reichert
jennifer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore 300.4(D) cable shall 11/4" from edge, 334.23 cable shall be protected within 6' of hatch in attic, 334.24 bend radius 5 times diameter of cable, 334.30 and 314.17C cable shall be supported at intervals of 41/2' and within 8" of each box. Sheath shall be 1/4 " in box. Cable shall not be stapled on edge., 314.29 Junction boxes shall be accessible in attic. 1/31/2005 9:48:10 AM 1/31/2005 9:48:16 AM
Electrical Rough-In1/21/20051/24/20051/24/2005AFAIL
DetailsBob Reichert
Rich; Phone #: ###-#### Internet Inspection Request from: Jan Rice told owner to recall after floor box is securely mounted and a cable clamp is installed. 1/24/2005 9:20:41 AM