Information based on query as of Monday, July 1, 2024.
Permit Information
Permit NumberELE05-00656
StatusFinaled
Name C H ELECTRIC
Site Address 9500 W CANTERBURY DR
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/14/20057/14/20057/14/2005PPASS
DetailsBob Reichert
chris; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa corrections made, ok to final
Final7/1/20057/1/20057/1/2005PFAIL
DetailsBob Reichert
chris; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa 352.30(A) rnc shall be strapped within 3' of box,404.9,406.5,314.21 faceplates shall completely cover openings and seat against finished surfaces, (microwave, gec cover, recpts in bedroom), 210.70(A)(2)(a) light shall be in stairway, called contr, left corr notice,
Electrical Rough-In3/22/20053/23/20053/23/2005APASS
DetailsMike Kinnear
chris; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
Permanent Service3/23/20053/23/20053/23/2005APASS
DetailsMike Kinnear
p/s u/g n ok
Electrical Rough-In3/21/20053/21/20053/21/2005PFAIL
DetailsBob Reichert
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles 300.4(D) nm cable shall be 1 1/4" from edge of framing member, North of fireplace, down low. 314.23(B)(1) boxes shall be securely fastened, North wall of garage, and North of garage door 3/21/2005 12:41:26 PM
Rough-In Permanent Service3/1/20053/1/20053/1/2005PFAIL
DetailsBob Reichert
chris ###-#### 300.4(D) nm cable shall be 1 1/4" from sdge of framing member, 314.23(B)(1) boxes shall be fastened, 314.23(B)(2) metal braces shall be fastened, BCC job id sticker shall be posted 3/1/2005 1:29:49 PM