Permit NumberELE05-03886
StatusFinaled
Name BENCHMARK ELECTRIC CO
Site Address 11427 W EXECUTIVE DR
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: Wiring and fixtures for new const.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/17/20063/20/20063/20/2006ACANC
DetailsBob Reichert
chad ; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa done Fri pm,
Final3/17/20063/17/20063/17/2006PPASS
DetailsBob Reichert
contr made corrections, called to see if we could re-inspect. ok to final, signed occ card
Final3/17/20063/17/20063/17/2006PFAIL
DetailsBob Reichert
met with 315 and contr, corr not done, they will call for Mon am
Final3/16/20063/17/20063/17/2006ACANC
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs see added conf.
Conference3/17/20063/17/20063/17/2006PDONE
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs met with Bob R and contractor we disccussed the violations Bob posted and contractor did not correct
Final3/10/20063/10/20063/10/2006PPART
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs met contr, left corr notice, did not sign card,330.30(B) mc cable shall be supported within 12" of box,314.27(C) floor box covers shall be listed as part of assembly,348.30(A) flex metal conduit shall be secured within 12" of box,210.62 show room receptacles shall be installed, 358.30 emt shall be secured within 3' of box, 400.8 flexible cords shall not be used as a substitute for fixed wiring, 408.4 circuit directories shall be completed, 110.3(A) only listed equipment shall be installed, 300.4 conductors shall be protected where subject to physical damage
Electrical Rough-In2/28/20063/1/20063/1/2006APASS
DetailsBob Reichert
Ceiling inspection.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs ok to cover ceilings
Rough-In Permanent Service2/1/20062/2/20062/2/2006ACANC
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs see p/s
Permanent Service2/2/20062/2/20062/2/2006APASS
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs p/s u/g n ok
Electrical Rough-In1/16/20061/16/20061/17/2006PPASS
DetailsMike Kinnear
Interior wall inspection.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs ok cover walls only
Electrical Rough-In11/17/200511/17/200511/17/2005PPART
DetailsBob Reichert
Underground inspection.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs ok to cover u/g from xfmr to riser in future bldg and to ne corner of lot
Electrical Rough-In11/16/200511/17/200511/17/2005AFAIL
DetailsBob Reichert
Underground inspection.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs had contr dig up u/g, not deep enough, elect on job, they will fix and recall
Electrical Rough-In10/25/200510/25/200510/25/2005PPASS
DetailsBob Reichert
Ufer inspection. Ufer is straight away from pole in foundation.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs ok to cover gec, left sticker on gec.