Permit Information
Permit NumberELE06-00117
StatusFinaled
Name ROMAR ELECTRIC
Site Address 9101 W FAIRVIEW AVE
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: PROVIDE WIRING FOR NEW SHOP INCLUDING NEW LIGHTING AND GEAR///Final cert of value $120,805 2/7/2007 cmc
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/10/200610/11/200610/11/2006APASS
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok card signed
Final10/3/200610/3/200610/3/2006PPART
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Patricia Smith left corr notice from 10/2/06 open, signed t/o card for bldg, told elect to be sure exhaust system not operational
Final10/2/200610/2/200610/2/2006PPART
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok for showroom area only, signed card, left corr notice, nec 514.3(B)(1) fuel dispenser shall provide clearances per table, 511.12 recpts shall be gfci, 511.3(A)(5) wiring shall be 18" above floor or class1, 430.102(B) door opener shall have disconnect, 330.39(B) mc cable shall be secured within 12" of box, BCC 4-05-33(A)&(B) exhaust system shall listed and labelled , check polarity on lifts and complete soffit lighting,NOTE: corrections shall be made in 2 weeks or further action can be taken such as removal of power
Electrical Rough-In9/13/20069/13/20069/13/2006PPASS
DetailsBob Reichert
mike - ceiling insp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to cover ceiling
Electrical Rough-In8/23/20068/24/20068/24/2006APART
DetailsJack Frank
mike - ceiling; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
N W ceiling areas ok
Electrical Rough-In8/7/20068/7/20068/7/2006PPART
DetailsBob Reichert
mike --ceiling insp ; Phone #: ###-#### Internet Inspection Request from: Marsha ok to cover clgs in 3 office areas
Electrical Rough-In7/31/20068/1/20068/1/2006APASS
DetailsBob Reichert
mike - wall ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley mezz walls ok to cover only
Electrical Rough-In7/31/20067/31/20067/31/2006PPASS
DetailsJim Schmer
mike ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley rest of soffett jms
Electrical Rough-In7/19/20067/19/20067/19/2006PPART
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley 1st floor walls and hard ceilings ok to cover, wrote correction notice to bldr/owner NEC article 514 shall apply to motor fuel dispensing facilities as to class 1 locations and wiring thereto, BCC no violations shall be retained
Electrical Rough-In7/17/20067/17/20067/17/2006PPART
DetailsBob Reichert
mike ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to cover soffits ne outside area, talked about it is ok to put tiles in around fixtures, but we'll see before all tiles go uo, probably 1/2 ceiling at a time, walls will be ready shortly
Final6/20/20066/20/20066/20/2006PCANC
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles wrong permit number
Electrical Rough-In6/13/20066/13/20066/13/2006PPART
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover showroom area hardlids, s & e walls north part of bldg
Permanent Service5/8/20065/8/20065/8/2006PPASS
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g n ok
Electrical Rough-In5/2/20065/2/20065/2/2006PPART
DetailsBob Reichert
mike - Note: wall; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles walls west end and north soffit ok to cover only
Electrical Rough-In4/26/20064/26/20064/26/2006PPART
DetailsMike Kinnear
ok cover part ceiling
ELE-Aging Inspection4/11/20064/11/20064/11/2006 DONE
DetailsBob Reichert
looked at job, suc
Electrical Rough-In2/8/20062/9/20062/9/2006PPASS
DetailsBob Reichert
Mike -- for underground; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong u/g ok for slab
Electrical Rough-In1/12/20061/12/20061/12/2006PPART
DetailsJack Frank
THIS IS FOR A UFER INSPECTION - ANY QUESTIONS PLEASE CALL MIKE HICKS; Phone #: ###-#### Internet Inspection Request from: Jeff Radford electrode ok for cover
Electrical Rough-In1/11/20061/12/20061/12/2006ACANC
DetailsBob Reichert
ANY QUESTIONS PLEASE MIKE HICKS-THIS IS FOR A UFER INSPECTION; Phone #: ###-#### Internet Inspection Request from: Jeff Radford do in pm