Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberELE06-00289
StatusFinaled
Name POWERBOUND ELECTRIC INC
Site Address 3808 N MOUNTAIN VIEW
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/20/20064/20/20064/20/2006PPASS
DetailsJack Frank
House is open and garage code is 6530.; Phone #: ###-#### Internet Inspection Request from: TJ Sturges ok
Final4/19/20064/20/20064/20/2006ANH
DetailsJack Frank
re-inspection; Phone #: ###-#### Internet Inspection Request from: TJ Sturges notice posted called left message
Final4/17/20064/18/20064/18/2006AFAIL
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: TJ Sturges corr. met electrician, 314.16 , box fill 314.17 conn for wiremold boxes island, counter also needs outlet island counter if other section is fixed to it, 210.52(C) (5) outlets shall not be over 20" above countertop by sink, also needs shelves installed in MB closet for clearence can be checked
Rough-In Permanent Service2/3/20062/3/20062/3/2006PPASS
DetailsJack Frank
Please call Steve on your way to job site ###-#### he needs to meet you. r/i ok house has unfinished basement,
p/s o/h new ok
Rough-In Permanent Service2/1/20062/2/20062/2/2006ANR
DetailsJack Frank
steve; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called
Electrical Rough-In1/26/20061/26/20061/26/2006PNR
DetailsMike Kinnear
please call when en route//steve; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa t/w general contractor they have adding window opener controlls that have not been wired at this time.
Rough-In Permanent Service1/25/20061/25/20061/25/2006PFAIL
DetailsBob Reichert
###-#### Nicole or call 8503670 Cody; Phone #: ###-#### Internet Inspection Request from: Nicole Richardson called contr, left corr notice, 314.16 boxes shall be of sufficient size to provide free space for conductors, 300.4(A) & (D) nm cable and edge of holes shall be 1 1/4" from edge of framing member, 725.55 class 2&3 cable shall be separated from power or class 1 circuits, BCC all make-up shall be done, NOTE: 210.52, floor boxes not set, shall maintain spacing at final