Permit Information
Permit NumberELE06-00801
StatusExpired
Name BRANDON C FONNESBECK
Site Address 10209 W SHILOH DR
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Rough-In Permanent Service3/17/20063/17/20063/17/2006PPASS
DetailsBob Reichert
Brandon -- reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong corr made, ric ok
Rough-In Permanent Service3/9/20063/10/20063/10/2006PFAIL
DetailsBob Reichert
Brandon; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong met owner, left corr notice,300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A) (1) receptacles shall be spaced so that no point is over 6' from a recpt horizontally along the floor line,334.30 nm cable shall be stapled within 8" of box, Note, smoke detector will be required in bedroom