Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE06-02811
StatusFinaled
Name WHITNEY WEST
Site Address 7140 W WAVERLY CT
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/23/200610/24/200610/24/2006APASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 10/23/2006 at 5:59:10 PM. Contact: ###-####. corr made, ok to final
Final10/17/200610/18/200610/18/2006AFAIL
DetailsBob Reichert
Scheduled by a contractor via Hello! on 10/17/2006 at 9:50:06 PM. Contact: ###-####. left corr notice, told owner, nec 406.8 in-use cover shall be installed outside in wet area, 406.5 faceplates shall seat against mounting surfaces, 408.4 panel cover shall be installed and circuit directory shall be complete concise and explicit, for each circuit, 422.31 disconnect shall be installed for hot water heater, 210.8(A) gfci shall operate in bath and outside, 348.30 fmc shall be securely fastened within 12" of box
Electrical Rough-In8/23/20068/24/20068/24/2006APASS
DetailsJack Frank
whitney; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok
Electrical Rough-In8/20/20068/21/20068/21/2006AFAIL
DetailsJack Frank
Scheduled by a contractor via Hello! on 8/20/2006 at 10:01:22 PM. Contact: ###-####. corr. met owner 300.4 nail plates, 300.14 equip grds too short, 110.12 replace pastic boxes with extra KO s broken out
Electrical Rough-In8/15/20068/16/20068/16/2006ANR
DetailsPat Lass
Scheduled by a contractor via Hello! on 8/15/2006 at 5:35:33 PM. Contact: ###-####.
requirements are not understood and homeowner not on site.left notice that howmowner shall be on site for inspection with Jace to clear up the problems.
grounds just twisted together. parallel protection......
Electrical Rough-In8/10/20068/11/20068/11/2006ANR
DetailsJack Frank
scheduled for 8-9 a.m per jack frank/// blb on 8/10/2006 Contact: ###-####. met owner needs makeup done some nail plates, and 11/4", outlet spacing
Final7/31/20068/1/20068/1/2006ACANC
DetailsJack Frank
Scheduled by a contractor via Hello! on 7/31/2006 at 2:42:09 PM. Contact: ###-####. see added conf.
Conference8/1/20068/1/20068/1/2006ADONE
DetailsJack Frank
Scheduled by a contractor via Hello! on 7/31/2006 at 2:42:09 PM. Contact: ###-####. ok