Final | 4/4/2007 | 4/5/2007 | 4/5/2007 | A | PASS |
Bob Reichert
|
|
|
the key is under the can on the meter main Phone #: ###-#### corr made, ok to final
|
Final | 3/30/2007 | 4/2/2007 | 4/2/2007 | A | FAIL |
Bob Reichert
|
|
|
Brandon; Phone #: ###-#### Internet Inspection Request from: Stacie Backus called, left corr notice, nec 210.52(E) shall install recpt at rear of dwelling, 210.70(A)(3) shall install lighting for jetted tub access and verify access hole per mfgr's instructions, 410.8(D) flourescent fixt in closet shall be min 6'' from shelf, 406.5 recpt faceplates shall seat against mounting surface, NOTE: shall provide cover for gec on dwelling and finish nailplates in garage
|
Electrical Rough-In | 1/16/2007 | 1/16/2007 | 1/16/2007 | P | PASS |
Bob Reichert
|
|
|
underground//Brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles u/g ok to cover house to garage only
|
Electrical Rough-In | 1/10/2007 | 1/11/2007 | 1/11/2007 | A | PASS |
Pat Lass
|
|
|
brandon; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
Permanent Service | 1/11/2007 | 1/11/2007 | 1/11/2007 | P | PASS |
Pat Lass
|
|
|
brandon; Phone #: ###-#### Internet Inspection Request from: Victoria Beall P/S U/G N Ok
|
Rough-In Permanent Service | 1/10/2007 | 1/10/2007 | 1/10/2007 | P | FAIL |
Bob Reichert
|
|
|
brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called, left corr notice, nec 300.4(A)&(B) edge of holes and nm cable shall be 1 1/4" from edge of framing member,314.17(C) nm cable shall be stapled within 8" of box, 210.52(A) recpt shall be placed in entry, 410.8 closet light shall be 12" from shelf, 210.52(E) recpt shall be installed at back,210.63 recpt shall be within 25' of a/c, BCC all make-up shall be done(kitchen), shall see u/g to garage
|
Rough-In Permanent Service | 1/8/2007 | 1/9/2007 | 1/9/2007 | A | CANC |
Bob Reichert
|
|
|
brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles wrong type request, see ri
|
Electrical Rough-In | 1/9/2007 | 1/9/2007 | 1/9/2007 | A | PART |
Bob Reichert
|
|
|
brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles back outside wall and upstairs floors ok to cover
|