Information based on query as of Sunday, July 7, 2024.
Permit Information
Permit NumberELE07-00611
StatusFinaled
Name KOYAMA ELECTRIC
Site Address 1622 W VICTORY RD
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - Alteration: wiring for bathroom/laundry room
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/6/20074/6/20074/6/2007PPASS
DetailsMike Kinnear
Scheduled by a contractor via Hello! on 4/6/2007 at 9:52:20 AM. Contact: ###-####. ok final
Electrical Rough-In2/26/20072/26/20072/26/2007PPASS
DetailsJack Frank
Scheduled by a contractor via Hello! on 2/26/2007 at 9:44:52 AM. Contact: ###-####. ok
Electrical Rough-In2/24/20072/26/20072/26/2007ANH
DetailsWilliam E Thomas
Scheduled by a contractor via Hello! on 2/24/2007 at 8:33:46 AM. Contact: ###-####.
not home, no answer with contractors phone
Electrical Rough-In2/22/20072/23/20072/23/2007PFAIL
DetailsBob Reichert
Please call John Phone #: ###-#### called contr, left corr notice, 300.4(A) & (D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 250.86 metal boxes shall be grounded, 314.17(C) nm cable shall be srecured within 8" of box, BCC no violations shall be retained- splices shall be accessible and in box