Final | 5/22/2008 | 5/23/2008 | 5/23/2008 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 5/22/2008 at 10:25:42 AM. Contact: ###-####. survey gfci for disposal recepts, 314.3 bond bushinf for emt in plastic sprinkler control box called final ok card signed
|
Electrical Rough-In | 3/26/2008 | 3/26/2008 | 3/26/2008 | P | PART |
Jack Frank
|
|
|
told ele contr that general needs to remove phone or caty conduit from below p/s panel
|
Permanent Service | 3/26/2008 | 3/26/2008 | 3/26/2008 | P | PASS |
Jack Frank
|
|
|
pam Phone #: ###-#### contr will bond can and water systems p/s u/g new ok
|
Electrical Rough-In | 3/26/2008 | 3/26/2008 | 3/26/2008 | P | PART |
Jack Frank
|
|
|
###-#### - pam Note: underground pipe for lighting u/g for 1pole light and sign lighting okwest side
|
Rough-In Permanent Service | 1/28/2008 | 1/28/2008 | 1/28/2008 | P | CANC |
Jack Frank
|
|
|
darlene Phone #: ###-#### see r/i request, p/s not ready
|
Electrical Rough-In | 1/28/2008 | 1/28/2008 | 1/28/2008 | P | PASS |
Jack Frank
|
|
|
darlene Phone #: ###-#### r/i ok all walls and hard ceilings
|
Electrical Rough-In | 1/24/2008 | 1/25/2008 | 1/25/2008 | A | FAIL |
Jack Frank
|
|
|
andy Phone #: ###-#### corr. called outlet spacing, nail plates, no screws in plastic boxes secure cables within 12" of panels, use plastic conn. for GEC
|
Electrical Rough-In | 1/16/2008 | 1/17/2008 | 1/17/2008 | P | CANC |
Jack Frank
|
|
|
darlene Note cover Phone #: ###-#### see added conf
|
Conference | 1/17/2008 | 1/17/2008 | 1/17/2008 | P | DONE |
Jack Frank
|
|
|
darlene Note cover Phone #: ###-#### conference ok only needs to correct p/s grounding, bath rm circuit, 11/4", protect at attic accesses, 6" free length, outlet spacing, secure MC 12" of boxes
|