Permit Information
Permit NumberELE09-00102
StatusFinaled
Name ALL VALLEY ELECTRIC
Site Address 5925 E MILLET DR
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: new house
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/26/20095/26/20095/26/2009PPASS
DetailsJack Frank
Sean Phone #: ###-####
Final5/24/20095/26/20095/26/2009AFAIL
DetailsJack Frank
please renspect, thank you Phone #: ###-#### Internet Inspection Request from: Sean Peltier no power to 1/2 of basement, called
Final5/21/20095/22/20095/22/2009AFAIL
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Sean Peltier job not reasdy only had access to upstairs, clearence for closet fixtures, install front entry coat closet fixture, needs gfci for garage door opener, no access to down stairs
Conference5/21/20095/21/20095/21/2009ADONE
DetailsBob Reichert
need info on an odd island Phone #: ###-#### Internet Inspection Request from: Sean Peltier talked about receptacles at edge of cook-top in backsplash being ok for island receptacles
Permanent Service5/5/20095/6/20095/6/2009PPASS
DetailsMike Kinnear
Phone #: ###-#### Internet Inspection Request from: Sean Peltier p/s u/g n ok
Rough-In Permanent Service2/4/20092/4/20092/4/2009PPASS
DetailsPat Lass
Please reinspect Phone #: ###-#### Internet Inspection Request from: Sean Peltier
Rough-In Permanent Service2/3/20092/4/20092/4/2009AFAIL
DetailsJack Frank
please reinspect, corrections made after talking with Bob. Phone #: ###-#### Internet Inspection Request from: Sean Peltier corr not made still needs nail plates called
Rough-In Permanent Service1/30/20092/2/20092/2/2009AFAIL
DetailsBob Reichert
shawn Phone #: ###-#### called contractor, left correction notice, NEC 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing member or be protected by steel plate, 210.70(A)(2) shall provide lighting outlet for garage door entrance, 110.14(A) gec terminal shall provide thoroughly good connection, BCC shall provide box for microwave and cable in basement and make-up for both
Rough-In Permanent Service1/20/20091/20/20091/20/2009PFAIL
DetailsMike Kinnear
Phone #: ###-#### Internet Inspection Request from: Sean Peltier fail service no grounding electrode -- ri no approved set of prints on job site framing may not be completed called contractor & advised