Permit Information
Permit NumberELE10-00125
StatusFinaled
Name TOTAL ELECTRIC INC
Site Address 4688 S MORNING LIGHT PL
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/29/20104/30/20104/30/2010APASS
DetailsBob Reichert
chris Phone #: ###-#### ok to final, receptacle installed
Final4/29/20104/29/20104/29/2010PPASS
DetailsDoug A Poedy
Verbal survey-needs outlet in dining room per 210.52 A2. will verify on 4-30-10
Conference4/28/20104/28/20104/28/2010ADONE
DetailsDoug A Poedy
Correction notice is correct. Corrections shall be made before final.
Final4/26/20104/27/20104/27/2010PPART
DetailsBob Reichert
Inspection requested from web by: Justin Frates corrections not made, had owner call 414 to confirm need for convenience outlet, tub opening not ready, will need to call for final when done
Final4/26/20104/26/20104/26/2010PFAIL
DetailsBob Reichert
Inspection requested from web by: Justin Frates called, left correction notice, NEC 210.52(A)(2) shall provide receptacle under bar/counter, 406.4 all receptacles shall be securely mounted, 406.4(D) receptacle face shall be flush with or project from cover, 406.5 receptacle covers shall be installed, 110.3 receptacles in laundry room shall operate, shall provide 12"x34" access in tub for maintenance, 410.2 shall provide clearance for closet fixture- purple room, BCC shall install trim for fixtures over desk, NOTE corrections shall be made within 5 working days or further action will be taken such as removal of power
Final4/23/20104/26/20104/26/2010ANH
DetailsBob Reichert
The tub upstairs will have a caulked removable tile to access the pump. Inspection requested from web by: Justin Frates Phone #: ###-#### called, nh, told to reschedule, fee due, left card
Electrical Rough-In1/22/20101/25/20101/25/2010APASS
DetailsBob Reichert
Justin Phone #: ###-#### corrections made, ric ok
Rough-In Permanent Service1/21/20101/22/20101/22/2010ACANC
DetailsBob Reichert
Justin Phone #: ###-#### see ri and p/s
Electrical Rough-In1/22/20101/22/20101/22/2010AFAIL
DetailsBob Reichert
Justin Phone #: ###-#### called, left message, left correction notice, NEC 334.30 shall secure nm cable within 12" of box, 210.52(A)(1) shall install receptacles such that no point along floor line is over 6' from an outlet- south entry room, 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing members, 110.12(B) there shall be no broken boxes-north part kitchen, 110.3(B) shall install listed equipment in accordance with instructions i.e. shall ensure that access to jetted tub is provide with 12"x24" opening, BCC shall provide boxes for under stair light, range, 240v circuit in basement
Permanent Service1/22/20101/22/20101/22/2010APASS
DetailsBob Reichert
Justin Phone #: ###-#### p/s u/g n ok