Permit Information
Permit NumberELE10-00246
StatusFinaled
Name BICANDI ELECTRIC LLC
Site Address 1807 S GOURLEY ST
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: new home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/29/20103/30/20103/30/2010APASS
DetailsBob Reichert
Inspection requested from web by: TOM BICANDI Phone #: ###-#### corrections made, ok to final
Final3/29/20103/29/20103/29/2010PFAIL
DetailsJack Frank
Inspection requested from web by: TOM BICANDI Phone #: ###-#### no power to some outlets called
Electrical Rough-In3/1/20103/2/20103/2/2010APASS
DetailsBob Reichert
Inspection requested from web by: TOM BICANDI Phone #: ###-#### corrections made, ric ok
Rough-In Permanent Service3/1/20103/1/20103/1/2010PCANC
DetailsBob Reichert
Inspection requested from web by: TOM BICANDI Phone #: ###-#### see ri and p/s
Electrical Rough-In3/1/20103/1/20103/1/2010PFAIL
DetailsBob Reichert
Inspection requested from web by: TOM BICANDI Phone #: ###-#### called left correction notice, NEC 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing members, 314.17 conductors entering boxes shall be protected from abrasion-garage lights, 314.14 shall not exceed box fill for garage lights, NOTE: corrections shall be made within 5 working days or further action will be taken
Permanent Service3/1/20103/1/20103/1/2010PPASS
DetailsBob Reichert
Inspection requested from web by: TOM BICANDI Phone #: ###-#### p/s u/g n ok
Rough-In Permanent Service3/1/20103/1/20103/1/2010ANR
DetailsBob Reichert
Inspection requested from web by: TOM BICANDI Phone #: ###-#### saw electrician, not done, see fee due
Electrical Rough-In2/11/20102/11/20102/11/2010PPASS
DetailsBob Reichert
Concrete over ufer ground, ¾ conduit from house to garage underground. Inspection requested from web by: TOM BICANDI Phone #: ###-#### ok to backfill concrete encased electrode
Electrical Rough-In2/10/20102/11/20102/11/2010PCANC
DetailsJack Frank
concrete poured over 20'' of ufer ground Inspection requested from web by: TOM BICANDI Phone #: ###-#### Inspection cancelled from web by: TOM BICANDI
Electrical Rough-In2/10/20102/11/20102/11/2010APASS
DetailsDoug A Poedy
ufer ground Inspection requested from web by: TOM BICANDI Phone #: ###-####. Ok to encase.
Electrical Rough-In2/10/20102/10/20102/10/2010PFAIL
DetailsBob Reichert
20'' ufer ground along footing. Inspection requested from web by: TOM BICANDI Phone #: ###-#### called, left correction notice, NEC 250.52(A)(3) concrete encased electrode shall be encased with 2" concrete and with direct contact with earth, NOTE: corrections shall be made within 5 working days or further action will be taken