Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberELE11-02772
StatusFinaled
Name VANZANDT ELECTRIC
Site Address 1300 W SUNRISE RIM RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - Addition: addition
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/13/20157/14/20157/14/2015APASS
DetailsRex Boyles
Master bath rough in insp. Thanks Phone #: ###-#### Inspection requested via web by John VanZandt r/i mstr. bath ok
ELE-Aging Inspection4/14/20154/14/20154/17/2015 DONE
DetailsRex Boyles
too busy
ELE-Aging Inspection1/13/20151/13/20151/14/2015 DONE
DetailsRex Boyles
too busy
ELE-Aging Inspection10/14/201410/14/201410/14/2014 DONE
DetailsRock A. Hudson
Still under construction
ELE-Aging Inspection7/15/20147/15/20147/15/2014 DONE
DetailsRock A. Hudson
Still under construction
ELE-Aging Inspection4/15/20144/15/20144/16/2014 DONE
DetailsBob Reichert
called, still under construction
ELE-Aging Inspection1/14/20141/14/20141/15/2014 CANC
DetailsBob Reichert
ELE-Aging Inspection10/15/201310/15/201310/17/2013 DONE
DetailsBob Reichert
still under construction
ELE-Aging Inspection7/15/20137/15/20137/22/2013 CANC
DetailsBob Reichert
Electrical Rough-In4/15/20134/16/20134/16/2013APASS
DetailsBob Reichert
Rough insp. for kitchen and basement Phone #: ###-#### >> Inspection requested via web by John VanZandt called, ok cover basement and upstairs except for panel area
ELE-Aging Inspection1/30/20131/30/20131/30/2013 DONE
DetailsBob Reichert
still under construction
Electrical Rough-In10/29/201210/30/201210/30/2012APASS
DetailsBob Reichert
Floor heat insp. call 30 mins ahead for access Phone #: ###-#### >> Inspection requested via web by John VanZandt ok cover floor heat dining room
Electrical Rough-In3/15/20123/16/20123/16/2012APASS
DetailsBob Reichert
Floor heat inspection + 3 bathrooms Phone #: ###-#### >> Inspection requested via web by John VanZandt ok cover floor heat
Electrical Rough-In12/21/201112/22/201112/22/2011APASS
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by John VanZandt corrections made, ri ok
Electrical Rough-In12/21/201112/21/201112/21/2011PFAIL
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by John VanZandt corrections not all done
Electrical Rough-In12/19/201112/20/201112/20/2011AFAIL
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by John VanZandt called, left correction notice, NEC 300.4(A)(D) edge of bored holes, nm, raceways shall be 1 1/4" from edge of framing members, 342.46 shall provide bushing for fmc, 314.17(C) shall staple nm within 8" of box, 334.30 shall not staple nm on edge, 334.80 shall derate nm if over 2 cables in hole, 250.86 shall ground metal boxes, BCC all make-up shall be done, boxes installed, wire boxes, prepare interface for old wall, check into 2' wall space for outlets top of stairs
Permanent Service12/15/201112/15/201112/15/2011PPASS
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by John VanZandt p/s o/h n ok
Permanent Service12/9/201112/9/201112/9/2011PNR
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by John VanZandt talked about concrete encased electrode not being deep enough or ground rods, and to recall