Final | 5/8/2014 | 5/8/2014 | 5/8/2014 | P | PASS |
Rock A. Hudson
|
|
|
Darlene Phone #: ###-#### Basement rough in ok cover
|
Final | 5/5/2014 | 5/6/2014 | 5/6/2014 | P | CANC |
Bob Reichert
|
|
|
Darlene Phone #: ###-#### see ri
|
Electrical Rough-In | 5/6/2014 | 5/6/2014 | 5/6/2014 | P | FAIL |
Bob Reichert
|
|
|
Darlene Phone #: ###-#### met owner, left correction notice, NEC 300.4(A)(C) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 334.30 nm cable shall be stapled within 12" of box or 314.17(C) 8" if more than 1 cable, 210.52(A) shall install receptacles within 6' of entry and 12' maximum between receptacles, BCC shall not install devices until ri complete so free length of conductor can be inspected
|
ELE-Aging Inspection | 4/8/2014 | 4/8/2014 | 4/8/2014 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 1/7/2014 | 1/7/2014 | 1/14/2014 | | CANC |
Bob Reichert
|
|
|
|
ELE-Request for Extension | 10/8/2013 | 10/9/2013 | 10/9/2013 | A | PASS |
Bob Reichert
|
|
|
ok for extension
|
ELE-Aging Inspection | 7/29/2013 | 7/29/2013 | 7/29/2013 | | DONE |
Bob Reichert
|
|
|
still under construction
|
Extend Permit 180 days | 4/12/2013 | 4/12/2013 | 4/12/2013 | P | PASS |
Bob Reichert
|
|
|
darlene - call prior to going Phone #: ###-#### talked to owner, ok extend permit
|
Final | 10/4/2012 | 10/5/2012 | 10/5/2012 | P | FAIL |
Bob Reichert
|
|
|
Dave Phone #: ###-#### explained that devices not to be installed, outlet spacing, stapling, 6" free conductor length, shall use connector for ground wires in box, call for ri next time
|
Electrical Rough-In | 5/31/2012 | 5/31/2012 | 5/31/2012 | P | CANC |
Bob Reichert
|
|
|
dave Phone #: ###-#### see p/s
|
Permanent Service | 5/31/2012 | 5/31/2012 | 5/31/2012 | P | PASS |
Bob Reichert
|
|
|
dave Phone #: ###-#### p/s o/h rec ok
|
Conference | 4/12/2012 | 4/12/2012 | 4/12/2012 | P | DONE |
Bob Reichert
|
|
|
Dave Atwood-Please call at least 30 mins prior to inspection Phone #: ###-#### talked about service, wiring rooms, call for inspection, watch clearances for service
|