Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE13-01617
StatusExpired
Name GEORGE DONALD W
Site Address 408 W UNION ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Expired2/1/20192/1/20192/1/2019APASS
DetailsDaryl DeGrange
No activity within 180 days. This permit is EXPIRED. A new permit is required to complete this job.
ELE-Aging Inspection11/30/201811/30/201812/3/2018 DONE
DetailsMark Moncarr
Please call with update on job being done.
ELE-Aging Inspection8/31/20188/31/20188/31/2018 DONE
DetailsMark Moncarr
Schedule a final inspection.
ELE-Aging Inspection6/1/20186/1/20186/4/2018 DONE
DetailsMark Moncarr
Please schedule for a final inspection.
ELE-Aging Inspection3/2/20183/2/20183/2/2018 DONE
DetailsMark Moncarr
Please schedule for a final inspection.
ELE-Aging Inspection12/1/201712/1/201712/1/2017 DONE
DetailsMark Moncarr
Please call with progress on work.
ELE-Aging Inspection8/31/20178/31/20178/31/2017 FAIL
DetailsMark Moncarr
No inspection requested at this time.
ELE-Aging Inspection6/1/20176/1/20176/1/2017 DONE
DetailsMark Moncarr
Inspector has talked to homeowner via phone, and also left a message on another occasion. No inspection requested at this time.
ELE-Aging Inspection2/20/20172/20/20172/21/2017 DONE
DetailsMark Moncarr
Message was left by inspector on 1/5/16. No inspection requested at this time.
ELE-Aging Inspection7/6/20167/6/20167/13/2016 CANC
DetailsEric Story
too busy
ELE-Aging Inspection4/5/20164/5/20164/5/2016 CANC
DetailsEric Story
too busy
ELE-Aging Inspection1/5/20161/5/20161/5/2016 DONE
DetailsEric Story
called and left a message
ELE-Aging Inspection9/22/20159/22/20159/22/2015 DONE
DetailsEric Story
talk with don he said he would be in touch to finish the home soon
Permanent Service10/7/201310/8/201310/8/2013APASS
DetailsRock A. Hudson
don Phone #: ###-#### p/s o/h n ok
Permanent Service9/26/20139/27/20139/27/2013AFAIL
DetailsRock A. Hudson
Robert Foster Phone #: ###-#### Grounding electode conductor shall not be ran through meter.
250.24- Grounding electode conductor shall terminate at the same bus bar as grounded conductor.
250.26- Main bonding jumper shall be installed.
334.30- NM cable shall be secured with in 8" of boxes.
Electrical Rough-In7/2/20137/3/20137/3/2013ANR
DetailsRock A. Hudson
don Phone #: ###-#### Service grounding and feeders not in, recepticals 18" minimum to bottom of boxes, NM support within 12" of junction boxes anddevice boxes.
Conference7/2/20137/3/20137/3/2013ADONE
DetailsRock A. Hudson
don Phone #: ###-#### Discussed receptical height in garage, NM support, service grounding and feeders, and owner would like to partial final garage when ready.