Permit Information
Permit NumberELE13-02228
StatusFinaled
Name SUBLIME ELECTRIC LLC
Site Address 1419 N 18TH ST
Project Name 
Customer NumberCook
ePlanReviewNo
Description
Electrical Permit - New: New garage/studio
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/17/201310/18/201310/18/2013APASS
DetailsRock A. Hudson
It will be open. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Final ok
Final10/16/201310/17/201310/17/2013AFAIL
DetailsRock A. Hudson
It will be unlocked. let me know if there are any problems. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan
410.16- Incandescent light fixture located in closet shall have 12" clearance from shelf.
440.14 - A disconnecting means shall be provided with in sight of AC unit.
210.8- All 15 and 20 amp 120 volt recepticals located in garage shall have GFCI protection.
210.52(C)(3)- At least one receptical outlet shall be installed at peninsula counter top space.
342.30- Service riser shall be secured with in 3' of meter can.
Rough-In Permanent Service8/27/20138/28/20138/28/2013APASS
DetailsBob Reichert
Please let me know if there are any problems. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan corrections made, ri ok, p/s o/h n ok
Rough-In Permanent Service8/21/20138/22/20138/22/2013PFAIL
DetailsRock A. Hudson
Please let me know if there are any problems. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan
400.8 Flexible cords shall not be ran in wall or attics.
exception- type TC cable is allowed if instaled in a raceway. 336.10 (2)
Rough-In Permanent Service8/20/20138/21/20138/21/2013PCANC
DetailsRock A. Hudson
Please let me know if there are any issues. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan