Final | 1/5/2014 | 1/6/2014 | 1/6/2014 | A | PASS |
Bob Reichert
|
|
|
Ryan is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut corrections made, ok final, house only, not pool
|
Final | 1/2/2014 | 1/2/2014 | 1/2/2014 | P | CANC |
Bob Reichert
|
|
|
Ryan is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut talked to contractor, he asked to cancel pm inspection today
|
Final | 1/2/2014 | 1/2/2014 | 1/2/2014 | A | CANC |
Bob Reichert
|
|
|
Ryan is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut Inspection cancelled from web by: Chris Chesnut
|
Final | 12/31/2013 | 12/31/2013 | 12/31/2013 | P | FAIL |
Bob Reichert
|
|
|
Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, too many items too list, some items: dead outlets in garage,washer not on gfci,fan box open at front door, bath gfci's won't set, kitchen plugs dead, outlet spacing in kitchen not per code, dining room outlet dead, hall receptacle dead, no light switches for up lights in big room, loose bath receptacle down bath, service riser shall be strapped, breakers labelled, ground bar for intersystem bond shall be installed, if balcony over 20 sq feet, shall add outlet
|
Final | 12/30/2013 | 12/30/2013 | 12/30/2013 | P | NR |
Bob Reichert
|
|
|
Final. Ryan is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut still wiring lights, switches and outlets, will recall when done
|
Electrical Rough-In | 11/14/2013 | 11/15/2013 | 11/15/2013 | A | PASS |
Bob Reichert
|
|
|
floor heat Phone #: ###-#### >> Inspection requested via web by Chris Chesnut ok cover floor heat
|
Electrical Rough-In | 11/14/2013 | 11/14/2013 | 11/14/2013 | P | NR |
Bob Reichert
|
|
|
floor heat Ryan Weiderich ###-#### Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, told to recall when other room heat laid
|
Rough-In Permanent Service | 9/11/2013 | 9/11/2013 | 9/11/2013 | P | PASS |
Bob Reichert
|
|
|
Chris Phone #: ###-#### ri ok, p/s u/g n ok
|
Rough-In Permanent Service | 9/10/2013 | 9/11/2013 | 9/11/2013 | A | FAIL |
Bob Reichert
|
|
|
Cj is contact. Thank you. Phone #: ###-#### >> Inspection requested via web by Chris Chesnutcalled, left correction notice, NEC 680.25 feeder to panelboard shall be run in raceway if supplying branch circuits for pool equipment, 314.17(C) shall staple nm cable within 8" of box, 314.20 boxes shall be flush with finished surface in combustible walls, BCC shall change permit to minimum 25 rooms and add for pool
|
Rough-In Permanent Service | 9/9/2013 | 9/10/2013 | 9/10/2013 | A | FAIL |
Bob Reichert
|
|
|
cj is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, shall provide damp rating for sub-panel in pool room, shall provide feeders per NEC 680, shall provide corrected room count for permit (minimum 25 rooms), including pool, shall provide flush mounted outdoor boxes, shall staple nm cable, will recall, talked about pool lighting
|