Permit Information
Permit NumberELE13-03408
StatusFinaled
Name ESTEP BUILDERS INC
Site Address 3720 N MAYWOOD DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - Repair: Service has been off for over one year.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/31/201410/31/201410/31/2014PPASS
DetailsDaryl DeGrange
please close garage door when done. button at front north corner. thanks. Phone #: ###-#### Inspection requested via web by Mark Estep GFCI breaker installed on non-grounding branch circuit, final ok
Final9/9/20149/9/20149/9/2014PFAIL
DetailsDaryl DeGrange
Phone #: ###-#### Inspection requested via web by Mark Estep receptacles have been replaced with new temper resistant grounding type device. Several grounding receptacles in the basement are without connection of grounding conductor. NEC 406.9 Shall connect grounding conductor or provide GFCI protection, replace with two wire device.
Final6/23/20146/24/20146/24/2014AFAIL
DetailsBob Reichert
mark Phone #: ###-#### met builder, shall fix hid lighting in garage (shall hardwire or move fixture to below receptacle) and 2 receptacles shall be properly wired in basement (shall provide power)
Electrical Rough-In2/19/20142/20/20142/20/2014APASS
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Mark Estep rough-in ok cover
Electrical Rough-In2/19/20142/19/20142/19/2014AFAIL
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Mark Estep Not all corrections completed
Electrical Rough-In2/18/20142/18/20142/18/2014PFAIL
DetailsDoug A Poedy
Need to secure romex within 6 inch from box. Box fill
Final2/18/20142/18/20142/18/2014PCANC
DetailsDoug A Poedy
Phone #: ###-#### >> Inspection requested via web by Mark Estep.
Final1/1/20141/2/20141/2/2014ANR
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Mark Estep Not ready for final at this time
Permanent Service1/2/20141/2/20141/2/2014PPASS
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Mark Estep p/s u/g rec ok
Final12/31/201312/31/201312/31/2013PNR
DetailsDaryl DeGrange
Please call me before you head over to job.
Thanks Phone #: ###-#### >> Inspection requested via web by Mark Estep canceled by contractor
Final12/30/201312/31/201312/31/2013AFAIL
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Mark Estep Hire licenced contractor to complete corrections, Strap service raiser witin 3 ft. of meterbase. All NM cables shall enter service panel through listed connector. Separate grounding conductor from neutral bar in remote panel
Final12/9/201312/9/201312/9/2013PFAIL
DetailsDaryl DeGrange
Door at rear of garage will be open. Please call me and I will probably be able to meet you.
Thanks. Phone #: ###-#### >> Inspection requested via web by Mark Estep NEC 250.56 Verify concrete encased electrode or add two ground rods. Separate all grounds and neutrals,NEC 312.5(C) Provide connector or abrasion protection for romex entring panel