Permit NumberELE14-00139
StatusFinaled
Name RUMMER ELECTRIC
Site Address 1897 S TRAVERTINE WAY
Project Name 
Customer Number34550
ePlanReviewNo
Description
Electrical Permit - New
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/4/20146/5/20146/5/2014APASS
DetailsBob Reichert
call for code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey ok final
Final6/2/20146/3/20146/3/2014AFAIL
DetailsBob Reichert
call for code Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, left message, left correction notice, NEC 210.8 outside receptacles shall be gfci protected, 406.4 shall securely mount receptacles, garage, down stairs, 404.9 shall install cover plate for switch
Rough-In Permanent Service1/20/20141/21/20141/21/2014APASS
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Rough in ok cover p/s u/g n ok
Rough-In Permanent Service1/17/20141/17/20141/17/2014PFAIL
DetailsRock A. Hudson
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey 300.4- Conduits containing conductors larger that #4 shall have bushing. Replace broken bushing on service riser.
300.4- nail plates required where bored holes are less than 1 1/4" from framing surface. holes bored at 45 degree angle around corners in kitchen and down east wall.
334.30 NM cable shall be secured with in 12" of box. basement east wall.
Down bath east- bath fan not made up.