Permit Information
Permit NumberELE14-01284
StatusFinaled
Name TREASURE VALLEY ELECTRIC INC
Site Address 3034 N 28TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - Addition: Basement remodel and 1 room addition
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/5/20149/5/20149/5/2014PPASS
DetailsRex Boyles
Inspection requested via web by Steve Craig corrections made final ok
Final9/2/20149/3/20149/3/2014AFAIL
DetailsDaryl DeGrange
Phone #: ###-#### Inspection requested via web by Steve Craig A/C unit requires wiring rated for wet locations, Furnace requires labeled disconnect or breaker lockout, Receptacle in wine cellar requires equipment grounding connection, Panel directory too brief.
Electrical Rough-In7/2/20147/3/20147/3/2014APASS
DetailsRex Boyles
Phone #: ###-#### >> Inspection requested via web by Steve Craig r/i ok corrections made
Electrical Rough-In7/2/20147/2/20147/2/2014PFAIL
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by Steve Craig met builder, he called electrical contractor, contractor called, told him knob and tube wiring shall not have insulation covering it, shall fix broken box, shall not have open splices, shall not provide exceeded box fill (pan over stairs)
Electrical Rough-In7/1/20147/1/20147/1/2014AFAIL
DetailsRex Boyles
Rough-in of addition. Phone #: ###-#### >> Inspection requested via web by Steve Craig 400.8 (2) flexable cords not permitted where concealed in walls ,floors or ceilings. 336.12(2) where installed outside raceway or cable tray..
Electrical Rough-In6/15/20146/16/20146/16/2014APASS
DetailsRex Boyles
Rough in of basement Phone #: ###-#### >> Inspection requested via web by Steve Craig bsmt. rough in ok except for bsmt. hallway and pantry
Electrical Rough-In6/12/20146/13/20146/13/2014AFAIL
DetailsBob Reichert
Cover inspection for basement Phone #: ###-#### >> Inspection requested via web by Steve Craig called, met builder, shall staple nm within 12" of box, shall not use damaged nm, shall not staple nm on edge, shall add receptacle in 10' hall, shall secure nm out of can lights
Electrical Rough-In6/4/20146/5/20146/5/2014APASS
DetailsDaryl DeGrange
Rough-in of concrete walls in basement prior to insulation and furring strips. Phone #: ###-#### >> Inspection requested via web by Steve Craig rough-in ok cover basement exterior walls
Permanent Service5/22/20145/22/20145/22/2014PPASS
DetailsRex Boyles
Relocate of existing service in preparation for addition to house. Idaho Power disconnect scheduled at 9:00 am. Should be ready for inspection by 12:00. pm Phone #: ###-#### >> Inspection requested via web by Steve Craig p/s o/h rec ok