Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberELE14-03128
StatusFinaled
Name MOUNTAIN VALLEY ELECTRIC
Site Address 421 S CURTIS RD Unit: 33
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: new home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/2/20153/3/20153/3/2015APASS
DetailsBob Reichert
Phone #: ###-#### Inspection requested via web by Dan Rohl corrections made, ok final
Final1/29/20151/29/20151/29/2015PFAIL
DetailsRock A. Hudson
6365 code Phone #: ###-#### Inspection requested via web by Dan Rohl
210.52(C)(1)- For counter top areas deeper than 18" from back of sink to wall receptacles shall be install for wall space.
314.20- Where boxes are installed in tile wall and are recessed 1/4" or more extension rengs shall be installed.
334.12(B)(4)- NM calbe shall not be used in a damp or wet location. In flex to AC unit.
110.3- Correct cover shall be used to cover back patio outdoor receptacle.
Rough-In Permanent Service11/12/201411/13/201411/13/2014APASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Dan Rohl Rough in ok cover p/s u/g n ok