Permit Information
Permit NumberELE15-00090
StatusFinaled
Name GLENN ELECTRIC
Site Address 2915 S OLD HICKORY WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/9/20154/10/20154/10/2015APASS
DetailsBob Reichert
CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn ok final
Rough-In Permanent Service2/2/20152/2/20152/2/2015APASS
DetailsCevyn Recla
Phone #: ###-#### Inspection requested via web by Bob Glenn
corrections made, RI OK, PS,UG, N, OK
Rough-In Permanent Service1/29/20151/30/20151/30/2015AFAIL
DetailsCevyn Recla
Phone #: ###-#### Inspection requested via web by Bob Glenn
called contractor
300.4(1) Bored Holes. In both exposed and concealed locations,
where a cable- or raceway-type wiring method is installed
through bored holes in joists, rafters, or wood members,
holes shall be bored so that the edge of the hole is not less
than 32 mm (11/4 in.) from the nearest edge of the wood
member. Where this distance cannot be maintained, the
cable or raceway shall be protected from penetration by
screws or nails by a steel plate(s) or bushing(s), at least
1.6 mm (1/16 in.) thick, and of appropriate length and width
installed to cover the area of the wiring.
Electrical Rough-In1/13/20151/14/20151/14/2015APASS
DetailsRock A. Hudson
THIS IS THE UNDER SLAB FOR THE KITCHEN ISLAND ONLY Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover