DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/14/20155/14/20155/14/2015PPASS
DetailsRock A. Hudson
Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
Final5/12/20155/13/20155/13/2015AFAIL
DetailsRock A. Hudson
If you have any questions, please call the office. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan 210.52(A)(2)(1)- Receptacle outlet shall be installed family room 2' wall space to left of fireplace. Receptacles located in cabinets do not qualify.
210.52(C)(1)- Receptacle outlet shall be installed to serve counter top by refrigerator with in 24" of edge and with in 4' of next receptacle.
210.51(D)- In main bath upstairs a receptacle outlet shall be installed for each basin and shall be ajacent to each basin.
422.30- Lock out provided for hood lock out shall be complete. Handle loop.
Rough-In Permanent Service2/27/20153/2/20153/2/2015APASS
DetailsCevyn Recla
If you have any questions, please call Clay. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan
RI interior OK to cover, need firecaulk on exterior boxes prior to soffit cover.
P/S, U/G, N, OK