Permit Information
Permit NumberELE15-01612
StatusFinaled
Name 45TH PARALLEL ELECTRIC LLC
Site Address 2024 W BOISE AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: UNIT #3, replace panel due to flooding
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/3/20156/3/20156/3/2015APASS
DetailsRex Boyles
Call for access code
Range is factory hard wired without a ground, A/C is a in house unit so the extras wire in conduit runs to a branch circuit in the living room. Phone #: ###-#### Inspection requested via web by David Nelson UNIT 3 corrections made final ok
Final6/3/20156/3/20156/3/2015ACANC
DetailsRex Boyles
Call for access code Phone #: ###-#### >> Inspection requested via web by David Nelson Inspection cancelled from web by: David Nelson
Rough-In Permanent Service6/1/20156/2/20156/2/2015ACANC
DetailsRex Boyles
UNIT #3, replace panel due to flooding Phone #: ###-#### Inspection requested via web by David Nelson needed r/i only
Electrical Rough-In6/2/20156/2/20156/2/2015PFAIL
DetailsRex Boyles
UNIT #3, replace panel due to flooding Phone #: ###-#### Inspection requested via web by David Nelson multiwire branch circuits need 2 pole breaker, tighten locknuts on conduits and install reducing washers where needed, some conduits with no ground conductor also need locknut tightened, conduit with 3 current carrying conductors have only 1 nuetral conductor for 1 phase system, strap conduits entering panel, install AFCI protection for bdrm. if possible, change range receptacle to 4 wire fed from sub panel