Permit Information
Permit NumberELE15-02922
StatusFinaled
Name LEA ELECTRIC LLC
Site Address 1155 N FRAZIER PL
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation: Wire New House
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/1/201512/2/201512/2/2015PPASS
DetailsRock A. Hudson
Damon Barr will be the electrician on site ###-#### Phone #: ###-#### Inspection requested via web by Liz Ramsey Closet luminaires chenged to florescent. Final ok
Final11/18/201511/19/201511/19/2015PFAIL
DetailsRock A. Hudson
Re-inspection for Habitat for Humanity, Contact Damonn. Phone #: ###-#### Inspection requested via web by Cathy Duchek
210.8- Receptacle outlets serving counter top in kitchen shall have GFCI protection. Unable to test due to trips as soon as load introduced.
350.30- LFMC shall be secured with in 12" of AC disconnect.
410.16- Luminaires located in closets shall have totally enclosed lamps and shall not be located with in 12" of shelves. Under stair and up closet.
440.22(C)- Overcurrent protection device shall ot exceed value on AC name plate. 30amp on 20 amp max
Final11/18/201511/18/201511/18/2015PFAIL
DetailsRock A. Hudson
Habitat for Humanity, Contact Damonn Phone #: ###-#### Inspection requested via web by Cathy Duchek AC, Furnace, transformer not complete.
406.12- All receptacle outlets installed in a residence shall be tamper resistant. All GFCI receptacles.
Electrical Rough-In9/16/20159/17/20159/17/2015APASS
DetailsBob Reichert
Rough-In Re-inspection. Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek corrections made, ri ok
Permanent Service9/17/20159/17/20159/17/2015APASS
DetailsBob Reichert
Rough-In Re-inspection. Contact Tom Betty Phone #: ###-#### Inspection requested via web by Cathy Duchek p/s u/g n ok
Electrical Rough-In9/14/20159/14/20159/14/2015PFAIL
DetailsRock A. Hudson
Complete residential home wiring. Contact Tom Betty @ ###-#### Phone #: ###-#### Inspection requested via web by Cathy Duchek 110.3- Expansion joint in service riser shall be installed to manufacturers instructions. Shall be installed to allow movement in both directions. 210.52(G)(1)- At least 1 receptacle outlet shall be installed for each car bay. These receptacle outlets shall not feed outlets outside garage. 334.12- Check 12-2 NM cable, maybe installed where subfect to physical damage. Down hall under drywall nailer. Upstairs bed driven into staple under cable maybe damaged. 334.80- Where multiple NM cables pass through bored holes with out maintaining spacing allowable ampacity shall be adjusted. Above garage warm wall 12 and 10 current carrying conductors.