Permit Information
Permit NumberELE15-03903
StatusFinaled
Name STEPHENS ELECTRIC INC
Site Address 1200 S OAKLAWN DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Complete remodel of the main level of the home and installing a new service
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/22/20163/23/20163/23/2016APASS
DetailsEric Story
The home owners should be home, the outlet by the fireplace has been changed to a GFI and the light in the bath area has been changed to a "non open lamp" fixture, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren corrections fixed final ok
Final3/17/20163/18/20163/18/2016AFAIL
DetailsRock A. Hudson
Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren
406.4(D)(2)- Grounding type receptacle outlet installed on an ungrounded circuit. either GFCI protect or change to a 2-wire receptacle.
410.10(D)- All luminaires located with in 3' horizontally and 8' vertical of tub edge or shower threshold shall be damp location rated.
Permanent Service12/15/201512/15/201512/15/2015PPASS
DetailsBob Reichert
We are upgrading the service on this home today, IP will be reconnecting the power this afternoon, I am hoping to get a service insp this afternoon just in case IP needs something approved before reinstalling the meter, please call for any questions, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren p/s o/h rec ok, at final check for 2nd ground rod, rods pounded down, labels, straps,
Electrical Rough-In12/3/201512/4/201512/4/2015APASS
DetailsRock A. Hudson
We are requesting an approval for cover inspection, the service will be done on a later date.
The customers are living in the basement, please knock before entering, but if the customer is not home, the lock box code is 2701.
Plz call for any questions, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Required receptacles in dining area around fireplace will be surface mount wiremold. Check box above living fireplace framing only 1" deep. Temp wiring to be removed when service change is done to refeed basement which is lived in. Main floor rough in ok cover