Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE16-00153
StatusFinaled
Name EVENGREEN TECHNOLOGY INC
Site Address 3300 E RED STONE DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: adding solar panels
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/19/20162/22/20162/22/2016APASS
DetailsBob Reichert
12 solar panels.
AC micro-inverter system. No DC voltage.
Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed.
Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs.
And 280 watt SolarWorld panels, ETL listed.

A single home run, in metal conduit, is ran from the array to the knife switch, located next to meter base. From the knife switch to the breaker in the main panel located in the garage, at the bottom of the bussing, opposite the feeder lugs. The solar breaker and knife switch are permanently marked for solar with weather proof labels, and the circuit numbers identified in the knife switch and on the panel schedule.

The inverters, panels and rails are all bonded with a number 6 ground that runs down to the service ground.

The main panel is in the garage, so give the homeowner a call for access at 208.344.4012


Thanks guys,
Ryan King
Phone #: ###-#### Inspection requested via web by Ryan King ok final
Electrical Rough-In1/19/20161/19/20161/19/2016PPASS
DetailsBob Reichert
listing inspection for panels and inverters.
The crew will get to site about 11, and with only twelve panels, will only take about 4 hours.
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King listing for 12 panels and misc ok