Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberELE16-03797
StatusFinaled
Name MAIR JAMES
Site Address 5796 E MILLET DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Complete Installation (includes: Complete electrical installation at new residence
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/20/201711/20/201711/20/2017PPASS
DetailsJames Ady
James Phone #: ###-#### corrections made final ok
Final11/15/201711/16/201711/16/2017AFAIL
DetailsJames Ady
james Phone #: ###-#### 110.3 Reverse polarity on Recep. to Rt of fireplace. 210.8A7 Recep to right of Mudroom sink needs GFCI. 210.8A6 Kitchen counter receps need GFCI. 314.20 Kitchen Backsplash receps need Sparkrings. 352.30A Service riser needs stapped above slip joint. 356.30 A/C flex needs strapped within 12in of disconnect.422.30 Furnace needs disc. 110.24 36in x 36in platform needs constructed in front of meter.
Final10/26/201710/26/201710/26/2017PNR
DetailsJames Ady
James ###-#### Platform for Service not in place. Need to recall when permanent platform is installed.
Permanent Service8/14/20178/15/20178/15/2017ACANC
DetailsJames Ady
James Phone #: ###-#### Already had service inspected
Rough-In Permanent Service7/21/20177/21/20177/21/2017PPASS
DetailsJames Ady
James Phone #: ###-#### Homeowner stated he would build platform in front of meter. Corrections made rough in ok p/s u/g n ok
Electrical Rough-In6/29/20176/30/20176/30/2017AFAIL
DetailsJames Ady
James Phone #: ###-#### Grn Metal Recep box in NET panel, Add receps in kitchen to comply with Countertop layout rules in 210.52. Move receps next to fixed glass door panels to comply with 6ft wall spacing, Add 3way switches at top an bottom of staircase. Add recep in half wall at top of staircase. remove 14awg for vac head from 12 awg circuit.
Temporary Service2/15/20172/15/20172/15/2017PPASS
DetailsJames Ady
James Phone #: ###-#### t/s u/g n ok
Temporary Service2/14/20172/14/20172/14/2017PFAIL
DetailsJames Ady
James Phone #: ###-#### 590.6 GFCI protection shall be provided for all temp wiring installations. 250.53 G Rod & Pipe Electrodes shall be flush or below grade. All openings shall be closed. Secure grounding conductor.