Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberELE17-01830
StatusFinaled
Name BURKE ELECTRICAL CONTRACTING
Site Address 10780 W PALM DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition-this is a M H
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/12/20179/12/20179/12/2017PPASS
DetailsTom Saunders
Please call 20 min prior so I can have someone meet you. Phone #: ###-#### Inspection requested via web by Kevin Burke...

ok to final
Final8/8/20178/9/20178/9/2017ANR
DetailsTom Saunders
Please call 20 min prior. Thanks! Phone #: ###-#### Inspection requested via web by Kevin Burke...

pedestal needs put back together, exposed romex inside needs protected, romex outside needs protected, light needs hung properly in bath...job needs completed
Final8/2/20178/3/20178/3/2017AFAIL
DetailsTom Saunders
Thomas-please call parcel owner to meet 30 meets prior Phone #: ###-####...

not ready...exposed wires at junction box and panel...never went inside
Final8/1/20178/2/20178/2/2017ACANC
DetailsTom Saunders
Phone #: ###-#### Inspection requested via web by Kevin Burke...

unable to do inspection until owner/contractor of residence gets permit issues satisfied with city of boise
Electrical Rough-In6/29/20176/30/20176/30/2017APASS
DetailsTom Saunders
Phone #: ###-#### Inspection requested via web by Kevin Burke...

corrections made...ok to cover
Electrical Rough-In6/28/20176/29/20176/29/2017AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Kevin Burke
300.4- Where NM cable is run thru bored or notched holes that do not maintain 1 1/4" for framing surface nail plates shall protect from physical damage.
334.30- NM cable shall be secured with in 12" of entering panel.
550.15(H)(1)- Under chassis wiring shall be identified for wet locations. NM not wet location rated.
Contractor stated all interior circuits have been checked for shorts and damage.
OK to energize panel.
Temporary Service6/13/20176/14/20176/14/2017APASS
DetailsMark Moncarr
t/s u/g rec ok. Mobile home pedistal being used for temp power to work on mobile home. Pedistal already metered, just needs power restored.
Conference6/13/20176/13/20176/13/2017PPASS
DetailsTom Saunders
view notes on temp service inspection of 6/13/17
Temporary Service6/13/20176/13/20176/13/2017PPASS
DetailsTom Saunders
Call half hour before // Thomas Phone #: ###-####...

discussed what needed to be done to get temp power at jobsite to do work on mobile home that caught fire...will remove all power feeds to mobile home and use existing pedestal for temp power for time being...will add 4sq box with in-use cover and gfi protection on pedestal
Temporary Service6/13/20176/14/20176/13/2017ACANC
DetailsTom Saunders
Call half hour before // Thomas Phone #: ###-####