Permit Information
Permit NumberELE17-02965
StatusFinaled
Name BOISE BASIN ELECTRIC
Site Address 7155 E GHOST BAR ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/31/20191/31/20191/31/2019PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
Rough-In Permanent Service9/8/20179/8/20179/8/2017PPASS
DetailsRock A. Hudson
###-####
Rough in ok cover p/s u/g n ok
Rough-In Permanent Service9/7/20179/8/20179/8/2017APART
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Alan Lusk
110.3- Branch circuit for furnace shall be sized as per manufacturers instructions.
15 amp installed 20 amp and 12 ga. required. Contactor to check with manufacturer for correct circuit.
408.3(B)(2)- Barriers shall be in place at line side termination of panel board.
OK insulate only