Permit Information
Permit NumberELE17-03472
StatusFinaled
Name 20174BT-5 LLC
Site Address 2017 S RIDGE POINT WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Remodel bathroom, kitchen.Add outlets and lights and electric fireplace in bonus room.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/22/20182/23/20182/23/2018PPASS
DetailsRock A. Hudson
Daniel Phone #: ###-####
Final ok
Final2/7/20182/8/20182/8/2018AFAIL
DetailsJames Ady
Daniel Phone #: ###-#### 210.8A1 and A7. GFCI protection requiered in bathrooms and within 6ft of sinks. (Bad bathroom GFCI breaker, Laundry room recep and Down bar receps. 314.20. Boxes set back more than 1/4in shall have spark rings,(all receps maounted in tile back splash) 406.12 All dwelling receps shall be Tamper resistant. (GFCI receps in Kitchen)
Electrical Rough-In10/22/201710/23/201710/23/2017PPASS
DetailsJames Ady
Wires stapled, other items addressed. Phone #: ###-#### Inspection requested via web by Daniel Dow Master bed, Bath, Living and kitchen. Kitchen recep layout ok as sheet rock was not removed on e wall. Basement mechanical room all ok to cover
Electrical Rough-In10/19/201710/20/201710/20/2017PNR
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Daniel Dow needed conference
Conference10/20/201710/20/201710/20/2017PDONE
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Daniel Dow Talked about wire support, AFCI protection on added receps in Master bed, 1/4in Sheathing in boxes, Grounding conductors tied through, Need recep added on wall in kitchen by Peninsula