Permit Information
Permit NumberELE18-01398
StatusFinaled
Name POWERHOUSE ELECTRIC
Site Address 935 E PARKCENTER BLVD
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration: Tenant improvement/remodel of existing building into a nail salon
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/21/20186/21/20186/21/2018PPASS
DetailsTom Saunders
Thank you! Have a great day!
Darryn Phone #: ###-#### Inspection requested via web by Darryn Coburn...corrections made...ok to final
Final6/20/20186/20/20186/20/2018PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Darryn Coburn
110.3- Receptacle outlet located on 3rd column from front east side not working.
210.8(B)(5)- All receptacles 50a or less single phase and 100a 3 phase located with in 6' of a sink shall have GFCI protection. Dryer.
314.20- Boxes mounted in a combustible material shall be flush or have an extension ring installed. Display case receptacle outlet.
422.5(A)(2)- All receptacle outlets suppying water coolers shall have GFCI protection. Unable to locate GFCI device.
Electrical Rough-In6/18/20186/18/20186/18/2018PPASS
DetailsJames Ady
his request is for a ceiling grid inspection. Thanks! Phone #: ###-#### Phone #: ###-#### Inspection requested via web by Darryn Coburn corrections made rough in ok
Electrical Rough-In6/15/20186/18/20186/18/2018AFAIL
DetailsJames Ady
This request is for a ceiling grid inspection. Thanks! Phone #: ###-#### Inspection requested via web by Darryn Coburn Open J Box above IT room door. Missing KO seal along East wall in front room.
Rough-In Permanent Service4/27/20184/30/20184/30/2018PCANC
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Electrical Rough-In4/30/20184/30/20184/30/2018PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Darryn Coburn Walls and hard lid through out rough in ok