Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberELE18-02706
StatusFinaled
Name SUBLIME ELECTRIC LLC
Site Address 1109 N MANVILLE ST
Project Name 
Customer Numbersanders
ePlanReviewNo
Description
Alteration or Repair: Electrical for house flip, stepping in after project had been started, completing the trim
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/17/20199/17/20199/17/2019PPASS
DetailsRock A. Hudson
Final ok
Final9/16/20199/17/20199/17/2019AFAIL
DetailsEric Story
Lock Box 5700. Call Andrew with any questions please ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan
Basement recepts in-op
Rough-In Permanent Service8/7/20188/13/20188/14/2018PPASS
DetailsJames Ady
Fred Phone #: ###-#### house ok to cover garage will be surface mount. check for 2 receps and mondoor light at final ok to cover p/s o/h rec ok
Conference7/23/20187/23/20187/23/2018PDONE
DetailsRock A. Hudson
Luke Phone #: ###-####
Discussed required items that shall be installed to code.
Verify minimum 20 amp appliance circuits are present. Kitchen receptacle layout complies.
Bathroom receptacles shall have a dedicated 20 amp circuit.
Required wall receptacles for kitchen area, living, dining.
Add smoke detectors for main floor and basement.
Grounding type receptacles installed on ungrounded circuits shall have GFCI protection or change to 2 wire receptacles. No AFCI required no work done in beds.
6-3 in basement shall be removed, owner eventually wants range in basement. Not zoned or designed for range in basement.
AC unit is new and shall provide a minimum of 3' from gas meter. A receptacle outlet shall be located with in 25' of AC unit. All wiring in garage that has been installed by prior owner or tenant shall be remove due to none is installed to NEC.
Receptacle exists in front of house shall have GFCI protection.