Permit Information
Permit NumberELE19-00646
StatusFinaled
Name APEX ELECTRIC INC
Site Address 608 N ROSS ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Permanent Service Up to 200 amps ONLY. Wire a townhouse
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/28/20197/1/20197/1/2019PPASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Greg Idsinga Ok final. Corrections made. Outlet buried in dining, now installed.
Final6/3/20196/4/20196/4/2019AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Greg Idsinga
210.8- All 15 or 20 amp 120 volt receptacle outets installed with in 6' of a sink shall have GFCI protection. Washer.
210.52(A)- No point measured along floor line shall be more than 6' from a receptacle outlet. Dining area.
210.70- A luminaire shall be installed on the exterior of each doorway with exterior access. Garage mandoor.
410.16- Incandescent and LED luminaires shall not be installed with in 12" of storage shelf in a clothes closet.
* Fee due- Fee charged was for service only, additional $80 due for dwelling totalling $135.
Rough-In Permanent Service2/27/20192/28/20192/28/2019PPASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Greg Idsinga p/s u/g n ok