Permit Information
Permit NumberELE19-01108
StatusFinaled
Name NEW LEAF ELECTRIC
Site Address 2619 N 28TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Addition: Relocating the meter and service panel, upgrading to 200 amp panel, adding circuits for new addition, and replacing or altering existing circuit wiring as necessary to support remodel project.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/28/20196/28/20196/28/2019PPASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Dan Hilke Ok final. Island recept was installed under a roughly 15in overhang. Contractor blanked off and I had him move it to a code compliant location.
Final6/26/20196/27/20196/27/2019PNR
DetailsMark Moncarr
When you have an idea what time you can get there call to let me know so I can make sure I or someone else is there to let you in. Thanks a bunch.
-Wyatt Dryden Phone #: ###-#### Inspection requested via web by Dan Hilke
Electrical Rough-In5/1/20195/2/20195/2/2019PPASS
DetailsMark Moncarr
House is unoccupied, someone should be there but if not then I can tell you how to get in if you just call or text. Phone #: ###-#### Inspection requested via web by Dan Hilke Ok cover whole house. Notified electrician to tell General for future, not to foam or caulk boxes or it will be removed before electrical inspection.
Rough-In Permanent Service3/31/20194/1/20194/1/2019PPASS
DetailsMark Moncarr
The meter and service panel are being moved because the existing mast location is within the new addition on the back of the house, and must be moved to the outside of the new addition in order to get trusses up. The intention is get power reconnected by the end of the day, but we won''t be ready for an inspection until near the end of the day. If you call/text after noon I should be able to provide an estimated time we''ll be ready for the inspection. Phone #: ###-#### Inspection requested via web by Dan Hilke p/s o/h n ok