Permit Information
Permit NumberELE19-01613
StatusFinaled
Name POWERHOUSE ELECTRIC
Site Address 1653 N MOCKBEE PL
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: new home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/10/201912/11/201912/11/2019APASS
DetailsMark Moncarr
garage code 9277, thank you! Phone #: ###-#### Inspection requested via web by Darryn Coburn Ok final.
Electrical Rough-In8/29/20198/29/20198/29/2019PPASS
DetailsMark Moncarr
This request is for a step light inspection. thank you! Phone #: ###-#### Inspection requested via web by Darryn Coburn Ok cover outside entry step lights.
Rough-In Permanent Service6/26/20196/27/20196/27/2019APASS
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Darryn Coburn Corrections made. Talked to electrician about fitting used to attach GEC to ufer. Builder was supposed to leave ufer exposed before building front steps. The fitting used was a UL listed acorn type that once tightened the bolt shears off and makes a permanent connection. p/s u/g n ok
Rough-In Permanent Service6/10/20196/10/20196/10/2019PFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Darryn Coburn
* No access to level 3.
*No safety rails on exposed interior rails of upper floors.
210.52(A)- Stair rails on level 2 concidered wall space and will need receptacle outlets installed. 250.50- All available grounding electrodes shall be used for grounding electrode system. Ufer found at entry.
Electrical Rough-In6/10/20196/10/20196/10/2019PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Soffits only rough in ok cover