Permit Information
Permit NumberELE19-04113
StatusFinaled
Name POWER PRO ELECTRICAL CONTRACTORS
Site Address 1463 N PINEVIEW LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: New 200 A Electrical installation for townhome
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/5/20202/7/20202/6/2020APASS
DetailsTom Saunders
All issues fixed. Phone #: ###-#### Inspection requested via web by Dan Jennings
Final2/6/20202/6/20202/6/2020APASS
DetailsTom Saunders
corrections made...ok to final
Final2/3/20202/4/20202/4/2020AFAIL
DetailsTom Saunders
Final inspection for Encore Townhomes. The garage door code is 6622, Please let me know if you have any question! Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings....
1) all exterior recepticles shall be rated weather resistant...406.9
2) plate for outlet under sink shall be rated to be used with handy box...110.3, 406.6
3) a recepticle shall be within 3ft of edge of each sink in master bathroom...210.52(D)
Permanent Service11/8/201911/8/201911/8/2019PPASS
DetailsTom Saunders
Pad has been poured. There weren''t any breakers installed above 6''7" but now there isn''t any bussing above that either. Phone #: ###-#### Inspection requested via web by Dan Jennings...
ps u/g new ok
Rough-In Permanent Service10/28/201910/28/201910/29/2019PCANC
DetailsTom Saunders
Just SW of Fairview / 5 Mile intersection. After 2pm preferrably if possible. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings...rough only...perm service not ready needs platform poured
Electrical Rough-In10/28/201910/28/201910/28/2019PPASS
DetailsTom Saunders
Just SW of Fairview / 5 Mile intersection. After 2pm preferrably if possible. Thank you! Phone #: ###-#### Inspection requested via web by Dan Jennings...rough ok to cover only
Rough-In Permanent Service10/24/201910/24/201910/24/2019PFAIL
DetailsRock A. Hudson
Townhome located just west of 5 Mile on the South side of Fairview. Phone #: ###-#### Inspection requested via web by Dan Jennings 240.24- Overcurrent devices shall not be located greater than 6'7" above grade. Bussing located above 6'7".
300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates.
NM cable shall be secured in place at least 1 1/4" from framing surface.